Overview
Device Front/Rear Panel Description
The image shows the labeled components and functional elements of the intercom

LED Light
Camera
Card Reader
Microphone
Nameplate & Call Button
Phototransistor
Status Indicators a. Calling b. Talking c. Unlocking
Speaker
Connectors
Connector RJ45 (PoE)
Reset Button
Note:
7a. – Calling: The indicator light will activate if the call button is pressed.
7b. – Talking: The indicator light will activate if the call is picked up or the Door Station is being actively checked.
7c. – Unlocking: The indicator light activates for 3 seconds when the door is unlocked.
9. – Relay Outputs: Supports 2 relays output.
Product Feature
Powered by PoE or power adapter (DC12V/2A)
Support IC (13.56MHz) & ID (125kHz) card, NFC
3 Indicator Lights
2 relays supported
Multi-button supported (2 or 5 buttons optional)
Technical Parameter
Power Supply: PoE (802.3af) or DC 12V/2A
Standby Power: 1.5 W
Rated Power: 3.5 W
Resolution: 1280 x 720
Working Temperature: -40℃ to +55℃
Storage Temperature: -40℃ to +70℃
Working Humidity: 10% to 90% (non-condensing)
Device Wiring
Network (PoE) / RJ45 (Non-standard PoE)
Standard RJ45 interface is for the connection with PoE switch or another network switch. PSE shall comply with IEEE 802.3af (PoE) and its output power not less than 15.4W and its output voltage is not less than 50V.

Power / Custom input configuration interface / Wiegand
The power interface of Door Station connects to 12V DC power.

The interface can be connected to one IC/ID card reader or be used for reading the information of built-in card reader.
Note: Door Station can only be connected to one card reader or management device at a time.
RS485 / Switching Value Output
Enable to connect equipment with RS485 interface.
Connect to the lock module (an independent power supply is necessary for the lock).
Enable to connect equipment with RS485 interface. Connect to the lock module(independent power supply is necessary for the lock).


Warning
When connecting to an inductive load device such as a relay or electromagnetic lock, you are recommended to use a diode 1A/400V (included in the accessories) in anti-parallel with the load device to absorb inductive load voltage peaks. The intercom will be better protected in this way.
The load current of the relay cannot be greater than 2A. See attached picture for more details.