# Overview

### Device Front/Rear Panel Description

{% hint style="info" %}
The image shows the labeled components and functional elements of the intercom
{% endhint %}

<figure><img src="/files/Lle1Lv6e4ptsuwirnpNU" alt="" width="551"><figcaption></figcaption></figure>

1. LED Light
2. Camera
3. Card Reader
4. Call Button
5. Microphone
6. Status Indicators\
   a. Calling\
   b. Talking\
   c. Unlocking
7. Speaker
8. Connectors
9. Connector RJ45 (PoE)
10. Reset Button

{% hint style="info" %}
6a. – Calling: The indicator light will activate if the call button is pressed.

6b. – Talking: The indicator light will activate if the call is picked up or the Door Station is being actively checked.

6c. – Unlocking: The indicator light activates for 3 seconds when the door is unlocked.

8\.   – Relay Outputs: Supports 2 relays output.
{% endhint %}

### Product feature

* Powered by PoE or power adapter (DC12V/2A)
* Support IC (13.56MHz) & ID (125kHz) card, NFC
* 3 Indicator Lights
* 2 relays supported
* Tamper alarm

### Technical parameter <a href="#toc228262224" id="toc228262224"></a>

* Power Supply: PoE (802.3af) or DC 12V/2A
* Standby Power: 1.5 W
* Rated Power: 3.5 W
* Resolution: 1280 x 720
* Working Temperature: -40℃ to +55℃
* Storage Temperature: -40℃ to +70℃
* Working Humidity: 10% to 90% (non-condensing)

### Device wiring

#### Network (PoE) / RJ45 (Non-standard PoE) <a href="#toc228262228" id="toc228262228"></a>

Standard RJ45 interface is for the connection with PoE switch or another network switch. PSE shall comply with IEEE 802.3af (PoE) and its output power not less than 15.4W and its output voltage is not less than 50V.<br>

<figure><img src="/files/SsRO8QAnLppFKMdeVXsf" alt="" width="116"><figcaption></figcaption></figure>

#### Power / Custom input configuration interface / Wiegand <a href="#toc228262229" id="toc228262229"></a>

The power interface of Door Station connects to 12V DC power.

The interface can be connected to one IC/ID card reader or be used for reading the information of built-in card reader.

<figure><img src="/files/Sk4tJ4nyWSrY3TljPeAK" alt="" width="365"><figcaption></figcaption></figure>

{% hint style="info" %}
Note: Door Station can only be connected to one card reader or management device at a time.
{% endhint %}

#### RS485 / Switching Value Output

Enable to connect equipment with RS485 interface.

Connect to the lock module (an independent power supply is necessary for the lock).

<figure><img src="/files/9VDaphWedkZEGoXwR6IC" alt="" width="343"><figcaption></figcaption></figure>

<figure><img src="/files/EAWpN5GsJjuoxLkCzPL9" alt="" width="258"><figcaption></figcaption></figure>

{% hint style="danger" %}
Warning!

1\. When connecting to an inductive load device such as a relay or electromagnetic lock, you are recommended to use a diode 1A/400V (included in the accessories) in anti-parallel with the load device to absorb inductive load voltage peaks. The intercom will be better protected in this way.

2.The load current of the relay cannot be greater than 2A. See attached picture for more details.
{% endhint %}

Enable to connect equipment with RS485 interface. Connect to the lock module(independent power supply is necessary for the lock


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://wiki.inels.com/intercom/intercom-devices/door-stations/ves-b201/overview.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.