Tutorial 9: adding a gateway
How a gateway fits on top of buttons you have already paired by hand, and where to find the detailed steps for the eLAN gateways.
Part 2 — Tutorials. Do Tutorial 1 first. This page is short on purpose.
What you will do
Take a light that already works from a wall button and make it controllable from the app too, without losing the button.
This page explains the idea and sends you to the right pages. It does not repeat the gateway's own steps.
The model: two steps, in this order
Pair by hand first. Do the pairing from Tutorial 1 and later tutorials. The button then works on its own, even if your router or the internet is off.
Then add the unit to the gateway. The gateway gives you the app, the cloud, timers, scenes and logic that button counting cannot do. The unit keeps the pairings you made by hand.
Which gateway?
eLAN-RF-204
Wi-Fi gateway. Up to 70 iNELS Wireless devices. App, iNELS Cloud, schedules and automation
eLAN-RF-103
Gateway of the same family
RFTC-3
A thermostat that also acts as a gateway, for heating and fan-coil systems
More: the eLAN-204 page and Transmitters, receivers and gateways.
What you need to know before you start
The gateway needs a network
The eLAN-204 connects to your home Wi-Fi (2.4 GHz). Set it up first with First Start and How to Use eLAN-RF-204.
A detector must be set for a gateway
A detector has a DIP switch that tells it whether it is paired with a unit or connected to a gateway. For the RFMD-100 it is DIP 3, for the RFWD-100 and the RFSF-100 it is DIP 2. Set it to ON for a gateway. The detector then sends its status when it changes and every 120 minutes. Set DIP switches before inserting the batteries. See Tutorial 5.
Where the detailed steps are
eLAN-204, start to finish: First Start · How to Use eLAN-RF-204 · Web Interface — Tabs Description · Service · Documents and links
Overview of the gateway: eLAN-204
Adding your hand-paired units to the gateway: Adding paired devices to a gateway
If it did not work
The wall button stopped working after adding to the gateway
The unit's memory was cleared
Pair the button again (Tutorial 1)
A detector is not seen by the gateway
DIP switch not set for a gateway, or batteries inserted before the switch was set
Set the DIP switch, remove the batteries, wait 30 s, insert them again
The gateway cannot find the unit
Wrong address, or the unit is out of range
Check the address on the unit's front. See Tutorial 8 for range
What you learned
Direct pairing comes first. A gateway is added on top.
A receiver is added to a gateway by its address, not by PROG.
A detector needs its DIP switch set for a gateway.
Last updated