Tutorial 5: detectors: motion light, door or window, flood
Pair a motion detector, a window/door detector and a flood detector with a switch unit. DIP switches, battery pairing, delayed return and testing.
Part 2 — Tutorials. Do Tutorial 1 first. Detector rules are in the Pairing reference, section D.
What you will build
Three small systems. You can do them one at a time.
A
RFMD-100 motion detector
Light on when someone moves, off after a set time
DIP switches, delayed return with a time
B
RFWD-100 window/door detector
Light on while a door is open
The magnet, ON/OFF function
C
RFSF-100 flood detector
Output switches when water is found
Pairing by counting battery insertions
A detector is a transmitter. It is paired like a controller, but you pair it by inserting its batteries.
You need
A switch unit that is already wired and working: RFSAI-61B-SL (unit page). It must be marked RFIO2: detectors work only with RFIO2 units (Appendix C).
The detector, with its battery or batteries.
A small screwdriver to open the detector cover.
A. Motion light with the RFMD-100
Choose the settings
Open the detector cover with a screwdriver. The DIP switches, the batteries and two small adjusters (SENS and LUX) are inside.

DIP 1
Normal motion (PIR) function
Light-sensor function: it sends the command when the light is lower than the LUX setting (0–500 lx)
DIP 2
After an activation the detector is idle for 1 minute
Idle for 5 minutes
For a normal motion light set DIP 1 OFF, DIP 3 OFF. The SENS adjuster sets how sensitive the motion sensor is. You can change SENS and LUX at any time.
Pair it, with a delay time
This is the delayed return with time setting: the light switches on when the detector sees motion, and off by itself after the time you choose (2 s to 60 min).
There is also a fixed-time version, which is shorter: do steps 1, 2 and 7 only. The RFMD-100 manual says the output then opens after 1 s. For a light that stays on for a while, use the version with a time setting above.
A3. Test
Close the cover. After you insert batteries the detector needs 15 s to settle before it detects motion.
For the first 5 minutes after the cover is closed, each detection blinks the red LED and the idle time is cut to 2 s. Use this to walk-test.
Walk in front of the detector. The light switches on. After your time it switches off.
Mount it up to 2.5 m high, indoors. The detection angle is 110°, up to 9.5 m.
B. Door or window with the RFWD-100
The RFWD-100 has two parts: a detector and a magnetic module. It activates when the magnet and the detector become separated. Put the detector on the moving part, the magnet on the frame.
B1. DIP switches
DIP 1
Normal: activates when the magnet moves away (door opens)
Inverse: activates when the magnet comes close
DIP 2
Paired with a unit (this tutorial)
Connected to a gateway
Set them with a screwdriver. Saving is the same as for the RFMD-100: the DIP is saved when the battery goes in.
B2. Pair it
The output switches on when the door opens and off when it closes: a cellar or garage light. For a light that stays on a while after the door closes, use the delayed return: pair the same way and follow steps 3 to 6 of section A2, with the CR2032 battery.
B3. Test
For 5 minutes after you insert the battery each approach or separation of the magnet blinks the red LED. Test the position before you stick the parts down: the detector and magnet must be close enough when the door is closed. The light must follow the door.
It works with the units marked RFIO2 listed in Appendix C. It cannot control shutter units.
C. Flood with the RFSF-100
When water bridges the two contacts on its underside, the RFSF-100 sends a command at once. It sounds an alarm and flashes. Use it to switch a pump, a warning device or a valve.
C1. Open it and set it
Open the cover with a screwdriver. Remove the insulating foil. The blue LED lights for 2 s and a message is sent.
Set the DIP switches:
DIP 1
Normal: when flooded, the paired unit's contact switches
Negated: when flooded, the contact opens. When the flood ends it closes again
DIP 2
For a switch unit (no periodic status message)
For a gateway (status every 120 min and on change)
DIP 3
Sound off
Sound on when the contacts are flooded
Insert the batteries. The blue LED lights for 2 s: the DIP settings are saved. If it does not light, remove the batteries, press the inner sides of the battery holders together lightly, then insert them again.
C2. Pair it
This detector is paired by counting battery insertions. One insertion is one press.
C3. Test and place
Put a few drops of tap water across the two contacts. The detector signals: the LED flashes once per second, alternating with a beep. The unit switches. A few seconds after the water is gone, the alarm ends and the unit is told.
Place the detector on a flat, non-conductive surface where flooding is expected, in a visible place. It senses only a liquid that has reached the contacts. Indoors only.
Suitable liquids include drinking, well, rain, waste and sea water. Not suitable: demineralised or deionised water, petrol, oil, paint, and drinks with a high alcohol content.
Weak battery: the alarm shows 2 flashes and 2 beeps. Without an alarm the detector flashes once, then four times, and repeats every 15 minutes.
If it did not work
The unit's LED does not blink faster when the batteries go in
Unit not in programming mode, wrong PROG time, or the unit is not RFIO2
Check Appendix A and the RFIO2 mark. Remove the batteries, wait 30 s, try again
The detector does nothing after pairing
DIP switch set after the batteries were in
Set the DIP, remove the batteries, wait 30 s, insert them again
The detector LED does not light when batteries go in (RFSF-100)
Detector needs a reset
Remove the batteries and lightly connect the inner sides of the holders, then insert them again
Light switches off after 1 s (motion)
You paired the fixed-time version
Pair again with the delay time (section A2)
The time is wrong
Timing started or stopped at the wrong moment
Remember: timing starts when you release PROG and ends when you insert the battery. Clear the detector (Tutorial 7) and pair again
Door light is reversed (on when closed)
DIP 1
Switch DIP 1, then re-insert the battery
LED shows a double blink when something moves (RFMD-100)
Weak battery
Replace the batteries
What you learned
A detector is a transmitter. You pair it by inserting its batteries, while the unit waits in programming mode.
DIP switches choose the behaviour. Set them before the batteries go in.
30 s pauses and 1 s gaps matter.
The delay time is measured: PROG held more than 5 s starts it, the battery insertion ends it.
Detectors need units marked RFIO2.
Try this before moving on
On the RFMD-100 set DIP 2 ON for a 5-minute idle time and watch the difference.
Pair a wall button to the same unit as in Tutorial 1. The light is then switched by the detector and by the button.
With the RFMD-100, turn SENS until it triggers only for a person walking up to it.
Next: Tutorial 6 — several buttons, a wired button and a central OFF