> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/detectors.md). Agents can also search and read this documentation through its [MCP server](https://wiki.inels.com/~gitbook/mcp).

# Detectors

Motion, window/door, flood and presence detectors — what each one detects, battery, DIP switches and pairing.

*Part 3 — Unit reference · Transmitters.*

A **detector** is a transmitter that sends a command when it is triggered — when it sees movement, when a window opens, when water reaches it. It does not switch anything itself: a [receiver](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/receivers.md) does. A detector is paired with a receiver **exactly like a wall button**; the difference is that instead of pressing a button you usually **insert the batteries**.

| Page                                                                                                                                         | What it detects                                                               | Power       |
| -------------------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------- | ----------- |
| [RFMD-100 / RFMD-200](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/detectors/rfmd-100-rfmd-200.md) | Motion of people (PIR). RFMD-100 for wall or corner, RFMD-200 for the ceiling | 2 × AA      |
| [RFWD-100](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/detectors/rfwd-100.md)                     | A window or door being opened (magnet and sensor)                             | 1 × CR2032  |
| [RFSF-100](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/detectors/rfsf-100.md)                     | Flooding — water on the contacts                                              | 2 × AAA     |
| [RFPD-100/230](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/detectors/rfpd-100-230.md)             | Presence of people (24 GHz radar), also when they sit still                   | 230 V mains |

## What the battery detectors have in common

* **Set the DIP switches before pairing.** The detector reads them when the batteries go in.
* **The 30-second rule (RFMD-100, RFMD-200, RFWD-100).** After you take the batteries out, wait at least 30 seconds before putting them back; if you are quicker the detector may not notice the batteries and pairing fails. The RFSF-100 is paired by counting battery insertions, 1 s apart — see its page.
* **The DIP option “connected to a system”** makes the detector report every change and also on its own every 120 minutes, for use with a system unit such as an eLAN gateway or RF Touch. With the option off, the detector is paired directly with a receiver and sends nothing but its detection.
* **Two ways to pair:** *immediate response* and *delayed return with a time you set*. The exact steps are on each detector's page; the general procedure is in [Pairing reference § D](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md).
* **Removing a pairing** is done on the **receiver**, with its PROG button — see [Appendix A](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-a-prog-button-times.md).