> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/controllers-with-an-output/rfsw-xx.md).

# RFSW-xx

RFSW-xx — glass touch controllers with two relays (RFSW-42/242/62/262) and hotel versions with MUR/DND symbols. Program the relays, pair the glass buttons to other units. Wiring, LED, specs.

*Part 3 — Unit reference · Controllers with an output.*

Glass wall controllers with **four or six touch buttons** and **two built-in switching relays**. Each unit is two devices in one housing:

* the **glass panel** behaves like an RFWB-40 — a **transmitter**;
* the **relay part** in the installation box is an independent multifunction switching **receiver** with two channels.

Sharp-edged types are **RFSW-42** (4 buttons) and **RFSW-62** (6 buttons); round-edged are **RFSW-242** and **RFSW-262**. Hotel versions with symbols are listed at the end of this page.

![RFSW-62](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2FwpJfzRMSf2GQQ9vLXpbQ%2Frfsw-62.png?alt=media)

## Two jobs — which one do you need?

| I want to …                                                                                                  | The RFSW is acting as a …          | Go to                                                                                              |
| ------------------------------------------------------------------------------------------------------------ | ---------------------------------- | -------------------------------------------------------------------------------------------------- |
| Switch the two lights/loads connected to the RFSW with its own glass buttons, a wall controller or a key fob | **Receiver** (its own two outputs) | [A. Program the built-in relays](#a-program-the-built-in-relays)                                   |
| Use the RFSW glass buttons to control **other** units elsewhere                                              | **Transmitter**                    | [B. Use the glass buttons to control other units](#b-use-the-glass-buttons-to-control-other-units) |
| Set backlight and click sound                                                                                | Settings                           | [Setup mode](#setup-mode-backlight-and-click-sound)                                                |

The **PROG** button is on the glass panel, on the **left**, between the two left-hand touch buttons. It belongs to the relay part: with it you choose the output, start learning and deleting, and switch the memory function.

## At a glance

|              |                                                                                                     |
| ------------ | --------------------------------------------------------------------------------------------------- |
| Outputs      | 2 × switching relay, 8 A / AC1, 2000 VA                                                             |
| Functions    | 6 per output: pushbutton, impulse relay, delayed on/off (2 s – 60 min) — any function on each relay |
| Control      | each output by up to 25 channels (buttons)                                                          |
| Buttons      | 4 (RFSW-42/242) or 6 (RFSW-62/262) touch keys + PROG; white backlight that adapts to ambient light  |
| Radio        | RFIO2, 866–922 MHz, repeater function, up to 160 m in open space                                    |
| Memory       | state after a power failure can be set                                                              |
| Installation | into an installation box                                                                            |

## Wiring

{% hint style="danger" %}
Switch the circuit off before wiring. Installation only by a qualified person. The relay contacts V1 and V2 switch the **phase** (L).
{% endhint %}

| Version                                            | Terminals                                                                                                                                             |
| -------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------- |
| 230 V AC                                           | **N N N L V1 V2** — L and N supply the unit; V1 and V2 are the two relay outputs (they switch the phase)                                              |
| 24 V AC/DC (hotel versions)                        | **+ − V1 V2** — supply 24 V AC/DC; the output contacts are galvanically isolated from the supply and share a common COM terminal                      |
| 230 V “GO” (galvanically isolated, hotel versions) | V1 is at the same potential as the supply; V2 is separate but must be connected to the same potential. Used when V1 and V2 must be secured separately |

Terminals are screwless, **0.2–1.5 mm²**. See the wiring drawing in the [instruction manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSW-62S/EN/Manual_RFSW-xx2_en-cz.pdf). Keep the relay outputs within the loadability in [Appendix D](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-d-load-capacity.md).

## A. Program the built-in relays

The relay part is a receiver with **two channels**. You teach each channel which buttons control it — buttons of a wall controller (RFWB), a key fob (RF KEY), or the **glass buttons of the RFSW itself**.

### Programming card — the relays

|                        |                                                                                                                                                 |
| ---------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------- |
| Manual on/off          | short press PROG                                                                                                                                |
| Select the channel     | hold PROG; the LED of the active channel lights and goes out after 1 s; release. **Green LED = channel 1, red LED = channel 2**                 |
| **Enter programming**  | **PROG 3 s** — learning mode; green LED = channel 1, red LED = channel 2                                                                        |
| Finish programming     | short press PROG (< 1 s)                                                                                                                        |
| **Clear one button**   | **PROG 7 s**, then press the button to remove                                                                                                   |
| **Clear whole memory** | **PROG 11 s** — all buttons removed; the unit stays in programming mode                                                                         |
| Functions              | 1× – 6× per output — see [Appendix B](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md) |
| Memory function        | see below                                                                                                                                       |
| Pairs with             | RFWB, RF KEY, glass buttons of the RFSW (controllers with a pairing button)                                                                     |

### Pair a button with a relay channel

{% stepper %}
{% step %}

### Controller into pairing mode (if it is a separate controller)

Hold the controller's pairing button **1 s** — the red LED gives a short blink ([Pairing reference § A](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md)). For the **glass buttons of the RFSW** itself you can skip this step.
{% endstep %}

{% step %}

### Choose the channel

Hold PROG until the LED lights, release when it has gone out. The LED of the newly selected channel lights for 1 s: **green = output 1, red = output 2**.
{% endstep %}

{% step %}

### Relay into learning mode

**Long press PROG** (**3 s**). The LED of the active channel stays on.
{% endstep %}

{% step %}

### Choose the function

Press the button you want to use **1–6 times**, about **1 s apart**. Press **one** of the glass buttons, or a button of the controller. The relay flashes the channel LED for every command it receives. Function numbers: [Appendix B](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md).
{% endstep %}

{% step %}

### Finish

**Short press PROG** (< 1 s). If you used a separate controller, also short press its pairing button. Repeat from step 2 for the other channel.
{% endstep %}
{% endstepper %}

### Memory function — what the output does after a power cut

1. Press PROG for **1 s** — programming mode, the LED flashes once per second.
2. Short press PROG (< 1 s). This **reverses** the memory setting and leaves programming mode.
3. The LED shows the new setting: **3 flashes = memory on**, **one long light = memory off**.

| Setting            | After a power cut                                                   |
| ------------------ | ------------------------------------------------------------------- |
| On — functions 1–4 | The output returns to its last state (saved 15 s after each change) |
| On — functions 5–6 | The output goes to the target state it would have after the delay   |
| Off                | The output stays off                                                |

## B. Use the glass buttons to control other units

The glass buttons can also control **other** receivers — instead of the built-in relays.

{% stepper %}
{% step %}

### Switch the glass to “sending” mode

Hold **PROG** pressed and, in quick sequence, press the glass buttons **1, 2, 3, 4** (4-button type) or **1 to 6** (6-button type). Release PROG. The **green LED** lights: the buttons now send learning codes for other units instead of switching the built-in relays.
{% endstep %}

{% step %}

### Other unit into programming mode

**Long press PROG on the other unit** for its own time ([Appendix A](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-a-prog-button-times.md)). Its LED flashes once per second.
{% endstep %}

{% step %}

### Choose the function

Press the glass button **as many times as the function number**, about 1 s apart ([Appendix B](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md)).
{% endstep %}

{% step %}

### Finish

**Short press PROG on the other unit.** Then **press PROG on the RFSW glass panel briefly twice** to stop sending learning codes.
{% endstep %}
{% endstepper %}

## Setup mode — backlight and click sound

1. Hold **PROG** and quickly press the glass buttons **1, 2, 3, 4** (6 buttons: 1 to 6). Release PROG.
2. **Short press PROG** → backlight mode (**red LED**). Button **1** switches the adaptive backlight on/off; button **2** the full backlight on/off; button **3** the click sound on/off.
3. **Short press PROG** again to leave setup.

## Using old controllers (no pairing button)

Controllers **without** a pairing button: insert the battery and, while the red LED is lit (3 s), hold button 1 until it flashes briefly, release, then put the RFSW into learning mode as in step 3 above — [Pairing reference § B1](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md). Finish by removing and re-inserting the controller battery.

## Hotel versions — RFSW-xx/S with symbols

The hotel types (RFSW-22/42/62 sharp, RFSW-222/242/262 round; white /SW or black /SB glass; 230 V, 24 V AC/DC, or “GO” galvanically isolated) have **symbols** on the glass:

* The buttons in positions **C** (DND, **Do Not Disturb**, red backlight) and **I** (MUR, **Make Up Room**, green LED) are **always reserved** for DND and MUR and are **interlocked** — only one can be active.
* The other positions **A, D, F, G** are free: they can control the unit's own relays or any iNELS Wireless element in the room (switching, dimming, shading) — programmed exactly like parts A and B above.
* A **Butler** button calls hotel service (set in the HRS).
* Together with the **RFGS-30** door unit it signals MUR and DND outside the room — see [RFGS-30](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/controllers-with-an-output/rfgs-30.md).
* The unit can be connected to the **HRS** (Hotel Reception Software) via the eLAN-RF gateway or the RFTC-3 thermostat.

For setting up MUR, DND and Butler with the RFGS-30, the RFTC-3 or the HRS, follow the instruction supplied with the unit (see Downloads).

## LED reference

| LED                                          | Meaning                                           |
| -------------------------------------------- | ------------------------------------------------- |
| Green                                        | Channel 1 selected / learning                     |
| Red                                          | Channel 2 selected / learning; backlight setup    |
| LED flash while learning                     | The relay received a command from a paired button |
| Green (after PROG + all buttons in sequence) | Sending mode for other units                      |
| LED flashes once per second                  | Programming mode (memory function)                |
| 3 flashes / one long light                   | Memory function on / off                          |

## Troubleshooting

| Symptom                              | Fix                                                                                                                                                                    |
| ------------------------------------ | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| A button controls the wrong output   | Select the channel first (green = 1, red = 2), then enter learning mode                                                                                                |
| Glass buttons control the wrong unit | Green LED on? You are in sending mode — press PROG briefly until it goes out                                                                                           |
| Learning mode does not start         | PROG held for the wrong time — [Appendix A](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-a-prog-button-times.md). 11 s clears the whole memory |
| Works close by, not in place         | Range — [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md)                                                             |

## Technical parameters

**RFSW-42, RFSW-242, RFSW-62, RFSW-262**

|                                                      |                                                                       |
| ---------------------------------------------------- | --------------------------------------------------------------------- |
| Supply voltage                                       | 230 V AC, 50–60 Hz                                                    |
| Apparent power / dissipated power                    | 1.1 VA / 0.8 W (±10 %)                                                |
| Outputs                                              | 2 × switching, 8 A / AC1, 2000 VA / AC1, peak 10 A / < 3 s, 250 V AC1 |
| Service life                                         | mechanical 1 × 10⁷, electrical (AC1) 1 × 10⁵                          |
| Control                                              | up to 25 channels (buttons) per output                                |
| Protocol / frequency                                 | RFIO2 / 866–922 MHz                                                   |
| Repeater function                                    | yes                                                                   |
| Range                                                | up to 160 m in open space                                             |
| Terminals                                            | screwless, 0.2–1.5 mm²                                                |
| Operating / storage temperature                      | −10 to +50 °C / −30 to +70 °C                                         |
| Protection / overvoltage category / pollution degree | IP20 / II / 2                                                         |
| Installation                                         | into installation box, any position                                   |
| Dimensions / weight                                  | 94 × 94 × 41 mm / 148 g                                               |
| Standards                                            | EN 60730, EN 63044, EN 300 220, EN 301 489                            |

**RFSW-xx/S hotel versions**

|                     |                                                                                                                                     |
| ------------------- | ----------------------------------------------------------------------------------------------------------------------------------- |
| Supply voltage      | 230 V AC, 50–60 Hz (1.2 VA / 0.6 W) or 24 V AC/DC (0.6 VA / 0.6 W), ±10 %                                                           |
| Relays              | 2 × switching, 8 A / 250 V AC1, 2000 VA, zero-cross; Ipeak < 110 A / 300 µs; life mechanical 10 million / electrical 100,000 cycles |
| Range               | up to 200 m in open space                                                                                                           |
| Protection          | front IP60 / rear IP20                                                                                                              |
| Dimensions / weight | sharp 94 × 94 × 39 mm / 131 g; round 100 × 100 × 39 mm / 138 g                                                                      |

## Downloads

* [Instruction manual RFSW-42/242/62/262, EN + CZ (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSW-62S/EN/Manual_RFSW-xx2_en-cz.pdf)
* [Datasheet RFSW-xx/S (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSW-62S/EN/Datasheet_RFSW-xx-S.pdf)
* Product pages: [RFSW-62 sharp](https://www.elkoep.com/glass-touch-controller-with-output-relays-6-buttons-sharp---rfsw-62) · [RFSW-62/S with symbols](https://www.elkoep.com/glass-touch-wireless-controler-with-symbols-rfsw-62s)