> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/controllers-with-an-output/rfsk-21-mpw.md).

# RFSK-21/MPW

RFSK-21/MPW — MIRO button controller with a built-in switching relay. Wiring, the two jobs (own relay as receiver, buttons as transmitter), functions, memory, specs.

*Part 3 — Unit reference · Controllers with an output.*

A **MIRO button controller with a switching relay**. A two-button rocker in MIRO design, installed in a wall box like a normal light switch — but it is also a radio unit. It is **two devices in one**:

* a **receiver**: its **relay output** switches a light or another appliance, and can be controlled by wireless buttons;
* a **transmitter**: its **two buttons** can switch its own relay **or** other iNELS Wireless units.

![RFSK-21/MPW](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2Ffzoh6EdvtnLLVpANQLjI%2Frfsk-21-mpw.png?alt=media)

{% hint style="info" %}
For setting up the unit (PROG button, programming times, LED indication), follow the instruction supplied with it — [short manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf).
{% endhint %}

## Two jobs — which one do you need?

| I want to …                                                                            | The RFSK is acting as a …    | Go to                                                                                  |
| -------------------------------------------------------------------------------------- | ---------------------------- | -------------------------------------------------------------------------------------- |
| Switch the light connected to the RFSK from a wall controller, a key fob, a detector … | **Receiver** (its own relay) | [A. Program the built-in relay](#a-program-the-built-in-relay)                         |
| Use the two RFSK buttons to switch **other** units                                     | **Transmitter**              | [B. Use the buttons to control other units](#b-use-the-buttons-to-control-other-units) |

## At a glance

|                  |                                                                                                                          |
| ---------------- | ------------------------------------------------------------------------------------------------------------------------ |
| Output           | 1 × switching relay, zero-cross, 10 A / AC1                                                                              |
| Functions        | 6 — pushbutton, impulse relay, delayed start or return with time 2 s – 60 min; any function can be assigned to the relay |
| Control          | the relay can be controlled by up to 25 channels (1 channel = 1 button on a controller)                                  |
| Manual control   | pressing any part of the rocker (up or down) changes the on/off state                                                    |
| Indication       | red LED                                                                                                                  |
| Radio            | RFIO2 (bidirectional), 868.5 MHz, repeater function, up to 160 m in open space                                           |
| Memory           | state of the output after a power failure can be set                                                                     |
| Installation     | VDE standard boxes and plasterboard boxes, with or without claws                                                         |
| EAN / order code | 8595188197243 / 9724                                                                                                     |

The unit can be combined with other controllers, units, detectors and iNELS Wireless system elements. The cover and frame come from the wide MIRO range (Polar White in the base).

## Wiring

{% hint style="danger" %}
Switch the circuit off before wiring. Mains voltage on the terminals. Installation only by a qualified person.
{% endhint %}

From the legend of the manual drawing:

| Terminal     | Connect                                                                 |
| ------------ | ----------------------------------------------------------------------- |
| **N**        | Neutral conductor                                                       |
| **P**        | Terminal for an **external button** (it carries the supply potential L) |
| **L**        | Phase conductor                                                         |
| Relay output | The load (the switched phase)                                           |

Screw terminals, rear cable entry, max. wire **2.5 mm²** (rigid and flexible). Wiring drawing: [short manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf). Loadability: 2300 VA AC1; 200 W (LED); 1050 VA (fluorescent); minimum load 5 W (LED).

## A. Program the built-in relay

The relay is a receiver. You teach it which buttons control it — wall controllers (RFWB), key fobs (RF KEY), detectors, other units.

### Programming card — the relay

|                        |                                                                                                                                                                            |
| ---------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Manual on/off          | press any part of the rocker                                                                                                                                               |
| **Enter programming**  | PROG button on the unit — see the [short manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf)                    |
| Finish programming     | short press PROG (< 1 s)                                                                                                                                                   |
| **Clear one button**   | PROG — see the [short manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf)                                       |
| **Clear whole memory** | PROG — see the [short manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf)                                       |
| Functions              | 1× – 6× — see [Appendix B — switch units](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md)                        |
| Memory function        | the state after a power failure can be set — see the [short manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf) |
| Pairs with             | All iNELS Wireless controllers, detectors and system elements                                                                                                              |

### Pair a controller button with the relay

The order is the same as for every iNELS Wireless receiver:

{% stepper %}
{% step %}

### Controller into pairing mode

On a controller with a pairing button hold it **1 s** — red LED short blink ([Pairing reference § A](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md)).
{% endstep %}

{% step %}

### RFSK into programming mode

Put the RFSK into programming mode with its **PROG** button, as described in the [short manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf).
{% endstep %}

{% step %}

### Choose the function

Press the controller button **1–6 times**, about **1 s apart** ([Appendix B](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md)).
{% endstep %}

{% step %}

### Finish

Short press **PROG** on the RFSK, then the pairing button on the controller.
{% endstep %}
{% endstepper %}

## B. Use the buttons to control other units

The two buttons allow control directly of the output relay **or other devices in the iNELS Wireless system**. The button part is a transmitter like an RFWB-20. To pair a button with another unit, put that unit into programming mode (its PROG, see [Appendix A](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-a-prog-button-times.md)) and send from the RFSK button. For how to switch the RFSK buttons between its own relay and other units, follow the instruction supplied with the unit — [short manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf).

The terminal **P** is for an external button/switch.

## Adding to a gateway

The RFSK-21/MPW is a unit of the iNELS Wireless system, controllable by up to 25 channels. How to add paired units to the eLAN-204: [Adding paired devices to a gateway](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/adding-paired-devices-to-a-gateway.md).

## LED

| LED | Meaning           |
| --- | ----------------- |
| Red | Status indication |

## Troubleshooting

| Symptom                              | Fix                                                                                                        |
| ------------------------------------ | ---------------------------------------------------------------------------------------------------------- |
| Light does not respond to the rocker | Check the wiring and the load (minimum 5 W for LED)                                                        |
| Wireless button does nothing         | Pair again: controller first, then RFSK; **1 s between presses**                                           |
| Button does the wrong thing          | Clear that button on the RFSK and pair again                                                               |
| Works close by, not in place         | Range — [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md) |

## Technical parameters

|                                                           |                                                                           |
| --------------------------------------------------------- | ------------------------------------------------------------------------- |
| Supply voltage                                            | 110–230 V AC, 50–60 Hz, +10 % / −15 %                                     |
| Apparent power / dissipated power                         | 7 VA (cos φ = 0.1) / 0.7 W                                                |
| Output                                                    | 1 × switching, zero-cross, 10 A / AC1                                     |
| Switching power                                           | 2300 VA / AC1; 200 W (LED); 1050 VA (fluorescent)                         |
| Peak current                                              | 10 A / < 3 s (Ipeak < 110 A / 300 µs; max. input capacity 125 µF)         |
| Minimum load                                              | 5 W (LED)                                                                 |
| Switching voltage                                         | 250 V AC1                                                                 |
| Service life                                              | mechanical 1 × 10⁷, electrical (AC1) 1 × 10⁵                              |
| Protection                                                | overheat                                                                  |
| Control                                                   | up to 25 channels; RFIO2; 868.5 MHz (max. EIRP 14 dBm); repeater function |
| Range                                                     | up to 160 m in open space                                                 |
| Operating / storage temperature                           | −15 to +50 °C / −20 to +60 °C                                             |
| Terminals                                                 | screw, rear mounting, 2.5 mm²                                             |
| Protection / IK / overvoltage category / pollution degree | IP30 / IK04 / III / 2                                                     |
| Dimensions / weight                                       | 90 × 90 × 45 mm / 120 g                                                   |
| Standards                                                 | EN 60730, EN 63044, EN 300 220, EN 301 489                                |

## Downloads

* [Short manual RFSK-21/MPW, multilingual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Manual_RFSK-21_MPW_10q_A4_\(75x70\).pdf)
* [Datasheet RFSK-21/MPW (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSK-21/EN/Datasheet_RFSK-21_MPW.pdf)
* Product page: [RFSK-21/MPW](https://www.elkoep.com/miro-button-controller-with-output-relay-rfsk-21mpw)