> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/controllers-with-an-output/rfmb-22-rfmb-42-rfmb-62.md).

# RFMB-22 / RFMB-42 / RFMB-62

RFMB-22 / 42 / 62 — metal pushbutton controllers with two switching relays. Wiring, the two jobs (own relays as receiver, buttons as transmitter via the hidden pairing button), specs, finishes.

*Part 3 — Unit reference · Controllers with an output.*

Designer **metal pushbutton controllers** with **two built-in switching relays**. The front plate and buttons are metal (brushed silver, satin brass, antique copper or graphite black). The number after RFMB is the number of buttons: **RFMB-22** has 2, **RFMB-42** has 4 and **RFMB-62** has 6 buttons — all have 2 relays. Each unit is **two devices in one**:

* a **receiver**: its two **relay outputs** can be controlled by wireless buttons (up to 12 external buttons per relay from RFWB, RF KEY and other controllers);
* a **transmitter**: its **buttons** can switch its own relays **or** other iNELS Wireless units (RFJA, RFSA …).

{% columns %}
{% column %}
![RFMB-22 brushed silver](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2FIpPMogiGVwijVecQagbF%2Frfmb-22-ss.png?alt=media)
{% endcolumn %}

{% column %}
![RFMB-22 graphite black](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2FCW6j1qr15Sl0iLmLQTXH%2Frfmb-22-bb.png?alt=media)
{% endcolumn %}
{% endcolumns %}

{% hint style="info" %}
For setting up the unit (PROG button, programming times, hidden pairing button, service LED), follow the instruction supplied with it.
{% endhint %}

## Two jobs — which one do you need?

| I want to …                                                                  | The RFMB is acting as a …         | Go to                                                                                  |
| ---------------------------------------------------------------------------- | --------------------------------- | -------------------------------------------------------------------------------------- |
| Switch the two loads connected to the RFMB from a wall controller, key fob … | **Receiver** (its own two relays) | [A. Program the built-in relays](#a-program-the-built-in-relays)                       |
| Use the RFMB buttons to control **other** units                              | **Transmitter**                   | [B. Use the buttons to control other units](#b-use-the-buttons-to-control-other-units) |

## At a glance

|                   |                                                                                                                 |
| ----------------- | --------------------------------------------------------------------------------------------------------------- |
| Buttons           | 2, 4 or 6 (RFMB-22 / 42 / 62), engraved symbols; white backlight that adapts to ambient light (internal sensor) |
| Outputs           | 2 × switching relay, 8 A / AC1, 2000 VA, zero-cross                                                             |
| Supply            | 110–230 V AC, 50–60 Hz                                                                                          |
| Radio             | RFIO2 (bidirectional), repeater function, up to 160 m in open space                                             |
| Memory            | state of the outputs after a power failure can be set                                                           |
| Parts you can see | buttons, **service LED** with ambient light sensor, **hidden pairing button**                                   |
| Installation      | flush mount in an installation box (EU or British standard), metal holder; front IP60 / rear IP20               |

### Finishes and order codes

The two letters after the slash give the button and plate finish: **G** satin brass, **B** graphite black, **S** brushed silver, **C** antique copper.

| Type                                 | EAN                                           | Code               |
| ------------------------------------ | --------------------------------------------- | ------------------ |
| RFMB-22/CC · RFMB-42/CC · RFMB-62/CC | 8595188195522 · 8595188195515 · 8595188195508 | 9552 · 9551 · 9550 |
| RFMB-22/GG · RFMB-42/GG · RFMB-62/GG | 8595188195492 · 8595188195485 · 8595188195478 | 9549 · 9548 · 9547 |
| RFMB-22/SS · RFMB-42/SS · RFMB-62/SS | 8595188195461 · 8595188195454 · 8595188195447 | 9546 · 9545 · 9544 |
| RFMB-22/BB · RFMB-42/BB · RFMB-62/BB | 8595188195423 · 8595188195409 · 8595188194907 | 9542 · 9540 · 9490 |

## Wiring

{% hint style="danger" %}
Switch the circuit off before wiring. Mains voltage on the terminals. Installation only by a qualified person.
{% endhint %}

Push-in (screwless) terminals, **0.2–1.5 mm²** solid or flexible. **L** and **N** supply the unit; **V1** and **V2** are the relay output contacts and use **zero-cross** switching: the load is switched when the voltage passes zero, so relay contacts do not burn or stick — especially with the electronic ballasts of LED luminaires. Connect the unit as shown in the wiring diagram in the [datasheet (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFMB-22/EN/Datasheet_RFMB-22_42_62.pdf). The unit fits an installation box to the EU or British standard with the supplied metal holder. Keep the relay outputs within the loadability in [Appendix D](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-d-load-capacity.md).

## A. Program the built-in relays

The two relays are receivers. You teach each relay which buttons control it.

### Programming card — the relays

|                                 |                                                                                                                                                     |
| ------------------------------- | --------------------------------------------------------------------------------------------------------------------------------------------------- |
| Enter programming               | PROG — follow the instruction supplied with the unit                                                                                                |
| Finish programming              | short press (< 1 s)                                                                                                                                 |
| Clear one button / whole memory | follow the instruction supplied with the unit                                                                                                       |
| Functions                       | 1× – 6× — see [Appendix B — switch units](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md) |
| Control                         | each relay by up to 12 external buttons (1 channel = 1 button)                                                                                      |
| Pairs with                      | RFWB, RF KEY and other iNELS Wireless controllers                                                                                                   |

The order of events is the same as for every receiver ([Pairing reference § A](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md)): put the controller button into pairing mode, put the RFMB into programming mode with its PROG, press the controller button 1–6 times, 1 s apart, finish with a short press of PROG.

## B. Use the buttons to control other units

The buttons are a **controller with a pairing button**: the controller is assigned to iNELS Wireless system elements using the **pairing button on the controller**. The pairing button is **hidden** on the unit (see the device drawing in the datasheet).

{% stepper %}
{% step %}

### RFMB into pairing mode

Put the RFMB into pairing mode with the **hidden pairing button**, as for any controller with a pairing button ([Pairing reference § A](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md)).
{% endstep %}

{% step %}

### Other unit into programming mode

Hold **PROG on the other unit** for its own time ([Appendix A](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-a-prog-button-times.md)). Its LED flashes once per second.
{% endstep %}

{% step %}

### Choose the function

Press the RFMB button **as many times as the function number**, about **1 s apart** ([Appendix B](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md)).
{% endstep %}

{% step %}

### Finish

Short press **PROG** on the other unit, then short press the hidden pairing button on the RFMB.
{% endstep %}
{% endstepper %}

The buttons allow you to directly control the built-in output relays as well as other iNELS Wireless units.

## LED

| LED                                            | Meaning                            |
| ---------------------------------------------- | ---------------------------------- |
| Service LED (next to the ambient light sensor) | Programming and pairing indication |

## Troubleshooting

| Symptom                        | Fix                                                                                                        |
| ------------------------------ | ---------------------------------------------------------------------------------------------------------- |
| Wireless button does nothing   | Pair again: controller first, then RFMB; **1 s between presses**                                           |
| Button does the wrong thing    | Clear that button on the RFMB and pair again                                                               |
| Relay does not switch the load | Check the wiring of V1/V2 and the loadability                                                              |
| Works close by, not in place   | Range — [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md) |

## Technical parameters

|                                         |                                                       |
| --------------------------------------- | ----------------------------------------------------- |
| Supply voltage                          | 110–230 V AC, 50–60 Hz, ±10 %                         |
| Apparent power / dissipated power       | 1.2 VA / 0.6 W                                        |
| Output                                  | 2 × switching, 8 A / AC1, 2000 VA, zero-cross         |
| Peak current                            | Ipeak < 110 A / 300 µs; max. input capacitance 125 µF |
| Service life                            | mechanical 10 million, electrical 100,000 cycles      |
| Control items                           | 2, 4 or 6 buttons                                     |
| Protocol                                | RFIO2; repeater function                              |
| Range                                   | up to 160 m in open space                             |
| Terminals                               | push-in, 0.2–1.5 mm²                                  |
| Operating / storage temperature         | −10 to +50 °C / −30 to +70 °C                         |
| Protection                              | front IP60 / rear IP20                                |
| Overvoltage category / pollution degree | II / 2                                                |
| Installation                            | flush mount, EU or BS box, any position               |
| Dimensions / weight                     | 94 × 94 × 40 mm / 160 g                               |
| Standards                               | EN 60730, EN 63044, EN 301 489, EN 300 220            |

## Downloads

* [Datasheet RFMB-22 / 42 / 62 (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFMB-22/EN/Datasheet_RFMB-22_42_62.pdf)
* Product page: [RFMB-22 / 42 / 62](https://www.elkoep.com/wireless-metal-pushbutton-controller-with-switching-relays-rfmb-22)