> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/controllers-with-an-output/rfgs-30.md).

# RFGS-30

RFGS-30 / RFGS-230 — hotel front-of-door unit with bell button, MUR and DND signalling and two relays. What it does, wiring variants, bell backlight meaning, how it works with the room unit, specs.

*Part 3 — Unit reference · Controllers with an output.*

The **hotel front-of-door unit**: a glass plate beside the room door with an illuminated **room number**, a **bell button**, and signalling of **MUR** (Make Up Room, green) and **DND** (Do Not Disturb, red). It has **two built-in switching relays**: one rings the room bell, the other can switch the light in front of the door — for example from the hotel schedule (HRS) by time or by ambient light. It replaces an ordinary bell button or light switch in the wall box and needs only a 230 V AC or 24 V AC/DC supply; communication is wireless.

**RFGS-30** has sharp glass edges, **RFGS-230** round; white (/SW) or black (/SB) glass.

![RFGS-30](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2FsGApXjGjk3oJStT8shQJ%2Frfgs-30s.png?alt=media)

## Two jobs

| The RFGS-30 is acting as a … | What it does                                                                                                                                                               |
| ---------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **Receiver**                 | Shows **MUR** (green LED) and **DND** (red LED) set on the room unit (RFSW-xx/S or RFTC-3). Its second relay can be controlled by the HRS or any iNELS Wireless controller |
| **Transmitter**              | The **bell button** controls the bell connected to the unit's switched output, **or any iNELS Wireless switching element**                                                 |

The unit can be controlled by up to **4 room units** (RFSW-xx/S glass controllers with symbols, or RFTC-3 thermostats). See [RFSW-xx](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/transmitters/controllers-with-an-output/rfsw-xx.md).

{% hint style="info" %}
Setup and programming is done with the pairing button and signalled by the service LEDs. For the details (position of the pairing button, teaching the room units, the relays and the bell), follow the instruction supplied with the unit.
{% endhint %}

## Bell button backlight

| Backlight         | Room                           | Does the bell ring? |
| ----------------- | ------------------------------ | ------------------- |
| White             | vacant                         | Yes                 |
| Blue              | occupied                       | Yes                 |
| Blue + DND symbol | occupied, but “Do not disturb” | **No**              |

The MUR symbol (green backlight) and DND symbol (red backlight) show the status set by the guest or by the staff in the room.

## Wiring variants

{% hint style="danger" %}
Switch the circuit off before wiring. Installation only by a qualified person.
{% endhint %}

| Variant        | Supply                    | Output contacts V1, V2                                                                                                                                |
| -------------- | ------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------- |
| **230 V**      | 230 V AC, terminals L, N  | switch the phase (L), zero-cross                                                                                                                      |
| **24 V**       | 24 V AC/DC, terminals + − | galvanically isolated from the supply, common COM terminal                                                                                            |
| **230 V “GO”** | 230 V AC                  | V1 is at the same potential as the supply; V2 is separate but must be connected to the same potential. Used when V1 and V2 must be secured separately |

Push-in terminals, 0.2–1.5 mm². Fits an installation box to the EU or British standard with a metal holder. The relays use **zero-cross** switching, which protects the contacts when switching LED luminaire ballasts.

Variants: RFGS-30 and RFGS-230, each in /SW and /SB, as /230V, /24V and /SWGO or /SBGO (230 V, galvanically isolated). Glass colour white or black; **room number and hotel logo are defined when ordering** (room number up to 55 × 18 mm, logo 33 × 10 mm).

## Connecting it to the hotel system

The RFGS-30 can be connected to the **HRS** (Hotel Reception Software) through the **eLAN-RF gateway** or the **RFTC-3 thermostat**. The functions can then be controlled from the reception PC or from the iNELS app.

## LED

| LED                | Meaning                          |
| ------------------ | -------------------------------- |
| Green (MUR symbol) | Make Up Room                     |
| Red (DND symbol)   | Do Not Disturb                   |
| Service LEDs       | Setup and programming indication |

## Technical parameters

|                                         |                                                                            |
| --------------------------------------- | -------------------------------------------------------------------------- |
| Supply voltage                          | 230 V AC, 50–60 Hz (1.2 VA / 0.6 W), or 24 V AC/DC (0.6 VA / 0.6 W); ±10 % |
| Output                                  | 2 × switching, 8 A / 250 V AC1, 2000 VA, zero-cross                        |
| Peak current                            | Ipeak < 110 A / 300 µs; max. input capacitance 125 µF                      |
| Contact life                            | mechanical 10 million, electrical 100,000 cycles                           |
| Control items                           | 1 button / 1 DND / 1 MUR                                                   |
| Protocol                                | RFIO2, 866–922 MHz; repeater function                                      |
| Range                                   | up to 200 m in open space                                                  |
| Terminals                               | push-in, 0.2–1.5 mm²                                                       |
| Operating / storage temperature         | −10 to +50 °C / −30 to +70 °C                                              |
| Protection                              | front IP60 / rear IP20                                                     |
| Overvoltage category / pollution degree | II / 2                                                                     |
| Installation                            | flush mount, EU or BS box, any position                                    |
| Dimensions / weight                     | sharp 94 × 94 × 39 mm / 131 g; round 100 × 100 × 39 mm / 138 g             |
| Standards                               | EN 60730, EN 63044, EN 301 489, EN 300 220                                 |