> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/switch-units/rfus-61.md).

# RFUS-61

Switch unit with increased protection IP65, 1 output, 12 A — RFUS-61. Wiring, programming card, pairing, clearing, specs.

*Part 3 — Unit reference · Switch units.*

A switch unit in a sealed housing (IP65) for places where a normal unit would not survive — a cellar, a garage, a bathroom, or on a wall outdoors next to a gate. One output channel, 12 A. It switches appliances, sockets or lights, and can also act as a potential-free contact for a gate or door drive.

![RFUS-61](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2FX6Cx7xPgQqzq2X5BzMtL%2Frfus-61.png?alt=media)

## At a glance

|                       | RFUS-61                                                |
| --------------------- | ------------------------------------------------------ |
| Output                | 1 × changeover contact, 12 A / AC1 (3000 VA)           |
| Functions             | 6                                                      |
| Wireless buttons      | up to 25                                               |
| Range in open space   | up to 200 m                                            |
| External button input | no                                                     |
| Protection            | IP65                                                   |
| Supply                | 110–230 V AC, 50–60 Hz, or 12–24 V AC/DC (RFUS-61/24V) |
| Size / weight         | 136 × 62 × 34 mm / 146 g                               |
| EAN                   | 230 V: 8595188196819 · 24 V: 8595188196826             |

{% hint style="info" %}
The supply voltage depends on the version: 110–230 V AC (5 VA, 0.6 W) or 12–24 V AC/DC (0.7 W). Check the label on your unit for its supply voltage.
{% endhint %}

## Wiring

{% hint style="danger" %}
Switch the circuit off before wiring. Wiring may only be done by a person with the right qualification. Open the housing only with the supply switched off.
{% endhint %}

| Terminal   | Connect                                                                                           |
| ---------- | ------------------------------------------------------------------------------------------------- |
| N, L       | Supply voltage (230 V / 120 V versions)                                                           |
| A1, A2     | Supply voltage on the 12–24 V AC/DC version                                                       |
| 15, 16, 18 | Output: one changeover contact. 15 is the common terminal; 16 and 18 are the two switch positions |

Two ways to connect the mains versions (see the diagrams in the manual):

* **3-wire connection** — phase is linked inside your wiring to terminal 15, the load is on terminal 18, the load's other wire goes to neutral. The unit switches the load directly.
* **4-wire connection** — the contact (15, 18) is **galvanically separated** from the supply. Use it when the contact only gives a command to another device, for example a gate drive.

The 12–24 V AC/DC version always has a galvanically separated contact (4-wire connection).

* Cable entry: bushing M16 × 1.5 for a cable up to 10 mm in diameter. Recommended supply cable: CYKY 3 × 1.5 (CYKY 4 × 1.5 for 4-wire).
* Screw terminals, max. 1 × 2.5 mm² or 2 × 1.5 mm² (with a ferrule max. 1 × 2.5 mm²).
* Mounting: on a wall with screws, through the two Ø 4.3 mm openings, in any position.
* The PROG button is **inside** the housing. Open the cover with a screwdriver before programming or manual control, and snap it closed again afterwards.
* While the unit is open, keep it away from liquids and do not touch the parts on the board.
* Keep at least 1 cm from other iNELS units.

Wiring diagrams: see page 1 of the instruction manual (PDF, see Downloads).

## Programming card

|                                        | RFUS-61                                                                                                           |
| -------------------------------------- | ----------------------------------------------------------------------------------------------------------------- |
| Manual on/off                          | PROG < 1 s                                                                                                        |
| **Enter programming**                  | **Hold PROG until the LED flashes once per second**                                                               |
| Finish programming                     | PROG < 1 s                                                                                                        |
| Timing mode (5× / 6×)                  | PROG more than 5 s                                                                                                |
| **Clear one button**                   | **PROG 5 s**                                                                                                      |
| **Clear whole memory (factory reset)** | **PROG 8 s**                                                                                                      |
| Functions                              | [1×–6×](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md) |
| Buttons                                | up to 25                                                                                                          |
| Pairs with                             | All iNELS RF Control and RF Control2 controllers and system units; RFIO2 detectors                                |

## Pair a controller button

{% stepper %}
{% step %}

### Open the unit

Switch the supply off, open the cover with a screwdriver and switch the supply on again. The PROG button and the LED are now reachable.
{% endstep %}

{% step %}

### Controller into pairing mode

Hold the controller's pairing button 1 s (red LED short blink). Older controllers: [Pairing reference](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md).
{% endstep %}

{% step %}

### Unit into programming mode

Hold PROG until the LED flashes once per second.
{% endstep %}

{% step %}

### Choose the function

Press the controller button **1–6 times, about 1 s apart** ([Appendix B](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md)). The LED lights at each press, so you can see the unit received it.
{% endstep %}

{% step %}

### Finish

Short press PROG (< 1 s). The LED shows the memory-function setting. Close the cover until it snaps in.
{% endstep %}
{% endstepper %}

| Presses | Function                                                         |
| ------- | ---------------------------------------------------------------- |
| 1×      | Button — on while pressed, off when released (hold at least 1 s) |
| 2×      | Switch on                                                        |
| 3×      | Switch off                                                       |
| 4×      | Impulse relay — every press flips the output                     |
| 5×      | Delayed off — on when pressed, off after the set time            |
| 6×      | Delayed on — off when pressed, on after the set time             |

### Delayed off / delayed on (5× / 6×)

After the 5 or 6 presses, hold PROG **more than 5 s** (LED flashes twice per second). Timing starts when you release. When the time you want has passed (2 s – 60 min), press the same controller button once to store it, then short press PROG to finish.

This unit has no input for a wired button; to use a wall-switch, see [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md).

## Memory function

Decides what the output does after a power cut.

1. Put the unit into programming mode (as above).
2. Short press PROG (< 1 s). This **reverses** the memory setting and leaves programming mode.
3. The LED shows the new setting: **3 blinks = on**, **one long light = off**.

| Setting            | After a power cut                                               |
| ------------------ | --------------------------------------------------------------- |
| On — functions 1–4 | Output returns to its last state (saved 15 s after each change) |
| On — functions 5–6 | Output goes to the state it would have at the end of the delay  |
| Off                | Output stays off                                                |

## Clear and factory reset

**One button.** Hold PROG **5 s** — LED flashes 4× per second. Press the controller button to remove. One long flash confirms.

**Whole memory = factory reset.** Hold PROG **8 s** — LED flashes 4× per second. All buttons are removed; the unit stays in programming mode (LED every 0.5 s, up to 4 min). Short press PROG (< 1 s) to leave.

Clearing does not change the memory-function setting.

## Use with eLAN-204 and service tools

* The **address printed on the side** of the unit is used to program it from system units and to add it to a gateway.
* To add it to an [eLAN-204](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204.md) gateway: open the Devices tab, press **ADD device**, choose the model from the list, enter the RF address shown on the unit, then choose an icon and a name ([Web interface tabs](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204/web-interface-tabs-description.md)).
* The **repeater function** can be switched on with the RFAF/USB service device (units marked RF Control2 / RFIO2).

## LED reference

| LED                             | Meaning                                             |
| ------------------------------- | --------------------------------------------------- |
| Flashes once per second         | Programming mode                                    |
| Lights at each controller press | Command received (in programming and clearing mode) |
| Flashes twice per second        | Timing mode                                         |
| Flashes 4× per second           | Clear mode                                          |
| Flashes every 0.5 s             | Memory cleared, waiting in programming mode         |
| 3 blinks / one long light       | Memory function on / off                            |

## Troubleshooting

| Symptom                                             | Fix                                                                                                                                                                                 |
| --------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Unit flashes 4× per second when you try to pair     | PROG held too long (that is clear mode). Release, wait, hold again until the LED flashes once per second                                                                            |
| Function is wrong                                   | Presses were less than 1 s apart or the count was off. Repeat pairing; one press every second                                                                                       |
| Works close by, not in place                        | Range — see [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md). Add an RFRP-20 repeater or an RFIO2 unit with the repeater function |
| Light comes on / does not come on after a power cut | Change the memory function                                                                                                                                                          |

## Technical parameters

|                                   | RFUS-61                                                         |
| --------------------------------- | --------------------------------------------------------------- |
| Supply                            | 110–230 V AC, 50–60 Hz, +10 % / −15 % · 12–24 V AC/DC, 50–60 Hz |
| Apparent power / dissipated power | 230 V version: 5 VA (cos φ = 0.1) / 0.6 W · 24 V version: 0.7 W |
| Output                            | 1 × changeover contact, AgSnO₂                                  |
| Rated current / switching power   | 12 A / AC1, 3000 VA / AC1, 384 W / DC                           |
| Peak current                      | 30 A / < 3 s                                                    |
| Switching voltage                 | 250 V AC1 / 24 V DC                                             |
| Min. DC switching power           | 500 mW                                                          |
| Service life                      | mechanical 3 × 10⁷, electrical (AC1) 0.7 × 10⁵                  |
| Protocol / frequency              | RFIO2, bidirectional, 866–922 MHz (max. EIRP 14 dBm)            |
| Repeater function                 | yes                                                             |
| Range                             | up to 200 m in open space                                       |
| Operating temperature             | −15 to +50 °C                                                   |
| Mounting / position               | screws / any                                                    |
| Protection                        | IP65                                                            |
| Overvoltage category / pollution  | III / 2                                                         |
| Terminals                         | max. 1 × 2.5 mm², max. 2 × 1.5 mm² (ferrule max. 1 × 2.5 mm²)   |
| Dimensions / weight               | 136 × 62 × 34 mm / 146 g                                        |
| Standards                         | EN 60730, EN 63044, EN 300 220, EN 301 489                      |

Load capacity for other load types: see the catalog *Product loadability* table (RFUS-61: AC1 = 250 V / 12 A).

## Downloads

* [Instruction manual RFUS-61 (PDF)](https://shop.ledco.sk/sub/shop.ledco.sk/images/related_files/Manual_rfus-61.pdf)
* Product page: [RFUS-61](https://www.elkoep.com/switch-unit-ip-rfus-61)