> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/switch-units/rfsa-66m-rfsa-66mi.md).

# RFSA-66M / RFSA-66MI

DIN-rail switch units, 6 channels, 8 A each — RFSA-66M (antenna connector) and RFSA-66MI (integrated antenna). Wiring, programming card, pairing, clearing, specs.

*Part 3 — Unit reference · Switch units.*

Switch units for the switchboard with **six independent outputs**, 8 A each, three modules wide. Each output switches its own appliance, socket or light, and you can give each output any of the six functions. They are also a good fit for scenes: one press on a controller can switch all six outputs on or off at once. The two types are the same inside — only the antenna differs: the **RFSA-66M** has a connector for an antenna, the **RFSA-66MI** has the antenna built in and suits switchboards with plastic doors.

{% columns %}
{% column %}
![RFSA-66M](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2FFyvfYRyknnEanoSFgDOW%2Frfsa-66m.png?alt=media)

**RFSA-66M** — antenna on SMA connector
{% endcolumn %}

{% column %}
![RFSA-66MI](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2Fqk7SxHLEdDpOwqB7Ljjx%2Frfsa-66mi.png?alt=media)

**RFSA-66MI** — integrated antenna
{% endcolumn %}
{% endcolumns %}

## At a glance

|                       | RFSA-66M                                                        | RFSA-66MI                             |
| --------------------- | --------------------------------------------------------------- | ------------------------------------- |
| Outputs               | 6 — 3 × make contact and 3 × changeover contact, 8 A / AC1 each | same                                  |
| Functions             | 6 per output                                                    | 6 per output                          |
| Wireless buttons      | up to 25 per output                                             | up to 25 per output                   |
| Antenna               | external, on SMA connector (rod antenna AN-I in the box)        | integrated                            |
| Range in open space   | up to 200 m                                                     | up to 200 m                           |
| External button input | no                                                              | no                                    |
| Supply                | 110–230 V AC, or 12–24 V AC/DC (SELV)                           | 110–230 V AC, or 12–24 V AC/DC (SELV) |
| Size / weight         | 90 × 52 × 65 mm (3 modules) / 179 g                             | 90 × 52 × 65 mm / 171 g               |

## Wiring

{% hint style="danger" %}
Switch the circuit off before wiring. Wiring may only be done by a person with the right qualification.
{% endhint %}

| Terminal                     | Connect                                                                       |
| ---------------------------- | ----------------------------------------------------------------------------- |
| A1, A2                       | Supply voltage: L and N (110–230 V AC) — or 12–24 V AC/DC on the 24 V version |
| 15–18, 25–28, 35–38          | Three outputs with a **make** contact (one pair of terminals per output)      |
| 45-46-48, 55-56-58, 65-66-68 | Three outputs with a **changeover** contact (three terminals per output)      |

* Screw terminals, max. 1 × 2.5 mm² or 2 × 1.5 mm² (with a ferrule max. 1 × 2.5 mm²).
* Mounting: DIN rail EN 60715, in any position. Protection IP20 from the front panel.
* Keep at least 1 cm from other iNELS units.
* The unit is **not for closed all-metal switchboards** — the metal blocks the radio signal. Use a plastic sub-switchboard. If the unit must sit in a metal cabinet, fit the external antenna AN-E (see below).
* For indoor use only.

Wiring diagram: see page 1 of the [instruction manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSA-66M/EN/Manual_RFSA-6xM_MI.pdf).

### Antenna (RFSA-66M)

| Antenna         | Use                                                                                   |
| --------------- | ------------------------------------------------------------------------------------- |
| AN-I — internal | Rod antenna, no cable, 1 dB. **Included** in the package. For a plastic switchboard.  |
| AN-E — external | 3 m cable, 5 dB. **On request only.** For a metal switchboard, to improve the signal. |

Screw the antenna onto the SMA connector. Maximum tightening torque: 0.56 Nm.

## Programming card

Every output has **its own PROG button and its own red status LED** on the front of the unit. You always work with the PROG button of the output you want to program.

|                                        | RFSA-66M / RFSA-66MI                                                                                                         |
| -------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------- |
| Manual on/off of an output             | PROG of that output < 1 s                                                                                                    |
| **Enter programming**                  | **Hold PROG until the LED flashes once per second**                                                                          |
| Finish programming                     | PROG < 1 s                                                                                                                   |
| Timing mode (5× / 6×)                  | PROG more than 5 s                                                                                                           |
| **Clear one button**                   | **PROG 5 s** — on that output only                                                                                           |
| **Clear whole memory (factory reset)** | **PROG 8 s** — on that output only                                                                                           |
| Functions                              | [1×–6×](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md) per output |
| Buttons                                | up to 25 per output                                                                                                          |
| Pairs with                             | All iNELS RF Control and RF Control2 controllers and system units; RFIO2 detectors                                           |

{% hint style="info" %}
Clearing works **only on the output whose PROG button you pressed**. To reset the whole unit, repeat the 8 s clear on each of the six outputs.
{% endhint %}

## Pair a controller button

{% stepper %}
{% step %}

### Controller into pairing mode

Hold the controller's pairing button 1 s (red LED short blink). Older controllers: [Pairing reference](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md).
{% endstep %}

{% step %}

### Unit into programming mode

Hold the **PROG button of the output you want to use** until the status LED of that output flashes once per second.
{% endstep %}

{% step %}

### Choose the function

Press the controller button **1–6 times, about 1 s apart** ([Appendix B](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md)). The LED lights at each press, so you can see the unit received it.
{% endstep %}

{% step %}

### Finish

Short press PROG (< 1 s). The LED shows the memory-function setting and the unit returns to operation.
{% endstep %}
{% endstepper %}

To make a scene, pair the same controller button to several outputs: repeat the steps for each output's PROG button.

| Presses | Function                                                         |
| ------- | ---------------------------------------------------------------- |
| 1×      | Button — on while pressed, off when released (hold at least 1 s) |
| 2×      | Switch on                                                        |
| 3×      | Switch off                                                       |
| 4×      | Impulse relay — every press flips the output                     |
| 5×      | Delayed off — on when pressed, off after the set time            |
| 6×      | Delayed on — off when pressed, on after the set time             |

### Delayed off / delayed on (5× / 6×)

After the 5 or 6 presses, hold PROG **more than 5 s** (LED flashes twice per second). Timing starts when you release. When the time you want has passed (2 s – 60 min), press the same controller button once to store it, then short press PROG to finish.

These units have no input for a wired button; to use a wall-switch, see [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md).

## Memory function

Decides what an output does after a power cut. Set it per output, with that output's PROG button.

1. Put the output into programming mode (as above).
2. Short press PROG (< 1 s). This **reverses** the memory setting and leaves programming mode.
3. The LED shows the new setting: **3 blinks = on**, **one long light = off**.

| Setting            | After a power cut                                               |
| ------------------ | --------------------------------------------------------------- |
| On — functions 1–4 | Output returns to its last state (saved 15 s after each change) |
| On — functions 5–6 | Output goes to the state it would have at the end of the delay  |
| Off                | Output stays off                                                |

## Clear and factory reset

**One button.** Hold the output's PROG **5 s** — LED flashes 4× per second. Press the controller button to remove. One long flash confirms.

**Whole memory of an output = factory reset.** Hold the output's PROG **8 s** — LED flashes 4× per second. All buttons of that output are removed; the output stays in programming mode (LED every 0.5 s, up to 4 min). Short press PROG (< 1 s) to leave.

Clearing does not change the memory-function setting.

## Use with eLAN-204 and service tools

* The **addresses printed on the unit** (one per output) are used to program it from system units and to add it to a gateway.
* To add it to an [eLAN-204](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204.md) gateway: open the Devices tab, press **ADD device**, choose the model from the list, enter the RF address shown on the unit, then choose an icon and a name ([Web interface tabs](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204/web-interface-tabs-description.md)). Add each output separately.
* The **repeater function** can be switched on with the RFAF/USB service device (units marked RF Control2 / RFIO2).

## LED reference

| LED                             | Meaning                                             |
| ------------------------------- | --------------------------------------------------- |
| Un — green                      | Power supply is present                             |
| STATUS — red (one per output)   | State of that output                                |
| Flashes once per second         | Programming mode                                    |
| Lights at each controller press | Command received (in programming and clearing mode) |
| Flashes twice per second        | Timing mode                                         |
| Flashes 4× per second           | Clear mode                                          |
| Flashes every 0.5 s             | Memory cleared, waiting in programming mode         |
| 3 blinks / one long light       | Memory function on / off                            |

## Troubleshooting

| Symptom                                             | Fix                                                                                                                                                                                                                                                          |
| --------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| Green Un LED is off                                 | No supply voltage on A1/A2. Check the wiring                                                                                                                                                                                                                 |
| Controller button switches the wrong output         | You pressed the PROG button of another output. Clear that output's button (PROG 5 s) and pair again                                                                                                                                                          |
| Unit flashes 4× per second when you try to pair     | PROG held too long (that is clear mode). Release, wait, hold again until the LED flashes once per second                                                                                                                                                     |
| Function is wrong                                   | Presses were less than 1 s apart or the count was off. Repeat pairing; one press every second                                                                                                                                                                |
| Works close by, not in place                        | Range — see [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md). Switchboard is metal: use a plastic one, or the external antenna AN-E. Or add an RFRP-20 repeater / an RFIO2 unit with the repeater function |
| Light comes on / does not come on after a power cut | Change the memory function of that output                                                                                                                                                                                                                    |

## Technical parameters

|                                  | RFSA-66M / RFSA-66MI                                                    |
| -------------------------------- | ----------------------------------------------------------------------- |
| Supply                           | 110–230 V AC, 50–60 Hz (not SELV) — or 12–24 V AC/DC (SELV)             |
| Apparent input                   | 110–230 V version: min. 2 VA / max. 5 VA                                |
| Dissipated power                 | 110–230 V version: min. 0.5 W / max. 2.5 W; 12–24 V version: max. 1.8 W |
| Outputs                          | 6 — 3 × make contact, 3 × changeover contact (AgSnO₂)                   |
| Rated current / switching power  | 8 A / AC1, 2000 VA / AC1 (per output)                                   |
| Peak current                     | 10 A / < 3 s                                                            |
| Switching voltage                | 250 V AC1                                                               |
| Min. DC switching power          | 500 mW                                                                  |
| Service life                     | mechanical 1 × 10⁷, electrical (AC1) 1 × 10⁵                            |
| Protocol / frequency             | RFIO2, bidirectional, 866–922 MHz                                       |
| Repeater function                | yes                                                                     |
| Range                            | up to 200 m in open space                                               |
| Operating temperature            | −15 to +50 °C                                                           |
| Mounting / position              | DIN rail EN 60715 / any                                                 |
| Protection                       | IP20 from the front panel                                               |
| Overvoltage category / pollution | III / 2                                                                 |
| Terminals                        | max. 1 × 2.5 mm², max. 2 × 1.5 mm² (ferrule max. 1 × 2.5 mm²)           |
| Dimensions / weight              | 90 × 52 × 65 mm / 179 g (66M), 171 g (66MI)                             |
| Standards                        | EN 60730, EN 63044, EN 300 220, EN 301 489                              |

Load capacity for other load types: see the catalog *Product loadability* table (8 A AgSnO₂ contacts).