> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/switch-units/rfsa-61m-rfsa-61mi.md).

# RFSA-61M / RFSA-61MI

DIN-rail switch units, 1 channel, 16 A — RFSA-61M (antenna connector) and RFSA-61MI (integrated antenna). Wiring, programming card, pairing, clearing, specs.

*Part 3 — Unit reference · Switch units.*

Switch units for the switchboard: one module wide, one output channel, 16 A. They switch appliances, sockets or lights. The two types are the same inside — only the antenna differs: the **RFSA-61M** has a connector for an antenna, the **RFSA-61MI** has the antenna built in and suits switchboards with plastic doors.

{% columns %}
{% column %}
![RFSA-61M](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2F8BQUlgrReMdAi8dV55sw%2Frfsa-61m.png?alt=media)

**RFSA-61M** — antenna on SMA connector
{% endcolumn %}

{% column %}
![RFSA-61MI](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2FH6w5S2o0NXUgmse3X1ee%2Frfsa-61mi.png?alt=media)

**RFSA-61MI** — integrated antenna
{% endcolumn %}
{% endcolumns %}

## At a glance

|                       | RFSA-61M                                                 | RFSA-61MI                |
| --------------------- | -------------------------------------------------------- | ------------------------ |
| Output                | 1 × changeover contact, 16 A / AC1 (4000 VA)             | same                     |
| Functions             | 6                                                        | 6                        |
| Wireless buttons      | up to 25                                                 | up to 25                 |
| Antenna               | external, on SMA connector (rod antenna AN-I in the box) | integrated               |
| Range in open space   | up to 200 m                                              | up to 200 m              |
| External button input | no                                                       | no                       |
| Supply                | 110–230 V AC, 50–60 Hz                                   | 110–230 V AC, 50–60 Hz   |
| Size / weight         | 90 × 17.6 × 64 mm (1 module) / 75 g                      | 90 × 17.6 × 64 mm / 69 g |

{% hint style="info" %}
The instruction manual (2024) also shows an RFSA-61M/24V version for 12–24 V AC/DC (SELV). Check the label on your unit for its supply voltage.
{% endhint %}

## Wiring

{% hint style="danger" %}
Switch the circuit off before wiring. Wiring may only be done by a person with the right qualification.
{% endhint %}

| Terminal   | Connect                                                                                           |
| ---------- | ------------------------------------------------------------------------------------------------- |
| A1, A2     | Supply voltage (marked Un): 110–230 V AC                                                          |
| 15, 16, 18 | Output: one changeover contact. 15 is the common terminal; 16 and 18 are the two switch positions |

* Screw terminals, max. 1 × 2.5 mm² or 2 × 1.5 mm² (with a ferrule max. 1 × 2.5 mm²).
* Mounting: DIN rail EN 60715, in any position. Protection IP20 from the front panel.
* Keep at least 1 cm from other iNELS units.
* The unit is **not for closed all-metal switchboards** — the metal blocks the radio signal. Use a plastic sub-switchboard. If the unit must sit in a metal cabinet, fit the external antenna AN-E (see below).
* For indoor use only.

Wiring diagram: see page 1 of the [instruction manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSA-61M/EN/Manual_RFSA-6xM_MI.pdf).

### Antenna (RFSA-61M)

| Antenna         | Use                                                                                   |
| --------------- | ------------------------------------------------------------------------------------- |
| AN-I — internal | Rod antenna, no cable, 1 dB. **Included** in the package. For a plastic switchboard.  |
| AN-E — external | 3 m cable, 5 dB. **On request only.** For a metal switchboard, to improve the signal. |

Screw the antenna onto the SMA connector. Maximum tightening torque: 0.56 Nm.

## Programming card

|                                        | RFSA-61M / RFSA-61MI                                                                                              |
| -------------------------------------- | ----------------------------------------------------------------------------------------------------------------- |
| Manual on/off                          | PROG < 1 s                                                                                                        |
| **Enter programming**                  | **Hold PROG until the LED flashes once per second**                                                               |
| Finish programming                     | PROG < 1 s                                                                                                        |
| Timing mode (5× / 6×)                  | PROG more than 5 s                                                                                                |
| **Clear one button**                   | **PROG 5 s**                                                                                                      |
| **Clear whole memory (factory reset)** | **PROG 8 s**                                                                                                      |
| Functions                              | [1×–6×](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md) |
| Buttons                                | up to 25                                                                                                          |
| Pairs with                             | All iNELS RF Control and RF Control2 controllers and system units; RFIO2 detectors                                |

## Pair a controller button

{% stepper %}
{% step %}

### Controller into pairing mode

Hold the controller's pairing button 1 s (red LED short blink). Older controllers: [Pairing reference](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md).
{% endstep %}

{% step %}

### Unit into programming mode

Hold PROG until the status LED flashes once per second.
{% endstep %}

{% step %}

### Choose the function

Press the controller button **1–6 times, about 1 s apart** ([Appendix B](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md)). The LED lights at each press, so you can see the unit received it.
{% endstep %}

{% step %}

### Finish

Short press PROG (< 1 s). The LED shows the memory-function setting and the unit returns to operation.
{% endstep %}
{% endstepper %}

| Presses | Function                                                         |
| ------- | ---------------------------------------------------------------- |
| 1×      | Button — on while pressed, off when released (hold at least 1 s) |
| 2×      | Switch on                                                        |
| 3×      | Switch off                                                       |
| 4×      | Impulse relay — every press flips the output                     |
| 5×      | Delayed off — on when pressed, off after the set time            |
| 6×      | Delayed on — off when pressed, on after the set time             |

### Delayed off / delayed on (5× / 6×)

After the 5 or 6 presses, hold PROG **more than 5 s** (LED flashes twice per second). Timing starts when you release. When the time you want has passed (2 s – 60 min), press the same controller button once to store it, then short press PROG to finish.

These units have no input for a wired button; to use a wall-switch, see [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md).

## Memory function

Decides what the output does after a power cut.

1. Put the unit into programming mode (as above).
2. Short press PROG (< 1 s). This **reverses** the memory setting and leaves programming mode.
3. The LED shows the new setting: **3 blinks = on**, **one long light = off**.

| Setting            | After a power cut                                               |
| ------------------ | --------------------------------------------------------------- |
| On — functions 1–4 | Output returns to its last state (saved 15 s after each change) |
| On — functions 5–6 | Output goes to the state it would have at the end of the delay  |
| Off                | Output stays off                                                |

## Clear and factory reset

**One button.** Hold PROG **5 s** — LED flashes 4× per second. Press the controller button to remove. One long flash confirms.

**Whole memory = factory reset.** Hold PROG **8 s** — LED flashes 4× per second. All buttons are removed; the unit stays in programming mode (LED every 0.5 s, up to 4 min). Short press PROG (< 1 s) to leave.

Clearing does not change the memory-function setting.

## Use with eLAN-204 and service tools

* The **address printed on the unit** is used to program it from system units and to add it to a gateway.
* To add it to an [eLAN-204](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204.md) gateway: open the Devices tab, press **ADD device**, choose the model from the list, enter the RF address shown on the unit, then choose an icon and a name ([Web interface tabs](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204/web-interface-tabs-description.md)).
* The **repeater function** can be switched on with the RFAF/USB service device (units marked RF Control2 / RFIO2).

## LED reference

| LED                             | Meaning                                             |
| ------------------------------- | --------------------------------------------------- |
| Un — green                      | Power supply is present                             |
| STATUS — red                    | Output status                                       |
| Flashes once per second         | Programming mode                                    |
| Lights at each controller press | Command received (in programming and clearing mode) |
| Flashes twice per second        | Timing mode                                         |
| Flashes 4× per second           | Clear mode                                          |
| Flashes every 0.5 s             | Memory cleared, waiting in programming mode         |
| 3 blinks / one long light       | Memory function on / off                            |

## Troubleshooting

| Symptom                                             | Fix                                                                                                                                                                                                                                                          |
| --------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| Green Un LED is off                                 | No supply voltage on A1/A2. Check the wiring and the fuse                                                                                                                                                                                                    |
| Unit flashes 4× per second when you try to pair     | PROG held too long (that is clear mode). Release, wait, hold again until the LED flashes once per second                                                                                                                                                     |
| Function is wrong                                   | Presses were less than 1 s apart or the count was off. Repeat pairing; one press every second                                                                                                                                                                |
| Works close by, not in place                        | Range — see [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md). Switchboard is metal: use a plastic one, or the external antenna AN-E. Or add an RFRP-20 repeater / an RFIO2 unit with the repeater function |
| Light comes on / does not come on after a power cut | Change the memory function                                                                                                                                                                                                                                   |

## Technical parameters

|                                   | RFSA-61M / RFSA-61MI                                          |
| --------------------------------- | ------------------------------------------------------------- |
| Supply                            | 110–230 V AC, 50–60 Hz, +10 % / −25 %                         |
| Apparent input / dissipated power | 2.7 VA (cos φ = 0.6) / 1.62 W                                 |
| Output                            | 1 × changeover, AgSnO₂                                        |
| Rated current / switching power   | 16 A / AC1, 4000 VA / AC1, 384 W / DC                         |
| Peak current                      | 30 A / < 3 s                                                  |
| Switching voltage                 | 250 V AC1 / 24 V DC                                           |
| Min. DC switching power           | 500 mW                                                        |
| Service life                      | mechanical 3 × 10⁷, electrical (AC1) 0.7 × 10⁵                |
| Protocol / frequency              | RFIO2, bidirectional, 866–922 MHz                             |
| Repeater function                 | yes                                                           |
| Range                             | up to 200 m in open space                                     |
| Operating temperature             | −15 to +50 °C                                                 |
| Mounting / position               | DIN rail EN 60715 / any                                       |
| Protection                        | IP20 from the front panel                                     |
| Overvoltage category / pollution  | III / 2                                                       |
| Terminals                         | max. 1 × 2.5 mm², max. 2 × 1.5 mm² (ferrule max. 1 × 2.5 mm²) |
| Dimensions / weight               | 90 × 17.6 × 64 mm / 75 g (61M), 69 g (61MI)                   |
| Standards                         | EN 60730, EN 63044, EN 300 220, EN 301 489                    |

Load capacity for other load types: see the catalog *Product loadability* table (16 A AgSnO₂ contacts).

## Downloads

* [Instruction manual RFSA-61M/MI, RFSA-66M/MI (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSA-61M/EN/Manual_RFSA-6xM_MI.pdf)
* [Datasheet RFSA-61M / RFSA-61MI (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSA-61M/EN/Datasheet_RFSA-61Mx.pdf) · [Antennas AN-I, AN-E (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSA-61M/EN/Datasheet_AN_x.pdf)
* Product pages: [RFSA-61M](https://www.elkoep.com/wireless-switch-unit-rfsa-61m) · [RFSA-61MI](https://www.elkoep.com/single-channel-switching-rfsa-61mi)