> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/switch-units/rfsa-11b.md).

# RFSA-11B

Box-type ON/OFF switch unit, 1 output, 16 A — RFSA-11B. Wiring, programming card, pairing, clearing, specs.

*Part 3 — Unit reference · Switch units.*

A small radio-controlled switch unit with one output (16 A) that fits into an installation box, a ceiling, or the cover of a lamp or appliance. The RFSA-11B is the **single-function** version of the [RFSA-61B](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/switch-units/rfsa-61b-rfsa-62b.md): it only does ON/OFF. It uses the same housing and the same instruction manual.

![RFSA-11B](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2Fb5wHqtIidDUwVgGVdIaT%2Frfsa-11b.png?alt=media)

## At a glance

|                       | RFSA-11B                                    |
| --------------------- | ------------------------------------------- |
| Output                | 1 × switching contact, 16 A / AC1 (4000 VA) |
| Function              | 1 — ON/OFF                                  |
| Wireless buttons      | up to 25                                    |
| Range in open space   | up to 200 m                                 |
| External button input | no                                          |
| Supply                | 230 V AC, 50–60 Hz                          |
| Size / weight         | 49 × 49 × 21 mm / 46 g                      |

{% hint style="info" %}
The instruction manual also shows 120 V AC and 12–24 V AC/DC versions (RFSA-11B/120V, RFSA-11B/24V). Check the label on your unit for its supply voltage. Need more than ON/OFF (impulse relay, delays)? Use the multi-function [RFSA-61B](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/switch-units/rfsa-61b-rfsa-62b.md).
{% endhint %}

## Wiring

{% hint style="danger" %}
Switch the circuit off before wiring. Wiring may only be done by a person with the right qualification. The unit is connected with flying leads (CY wire), 90 mm long.
{% endhint %}

| Lead      | Connect                                                                                                                                      |
| --------- | -------------------------------------------------------------------------------------------------------------------------------------------- |
| N         | Neutral (supply)                                                                                                                             |
| L         | Phase (supply)                                                                                                                               |
| 15 and 18 | The unit's switch contact. Put it in the line to your load: phase to one lead, the load to the other. The load's other wire goes to neutral. |

* Mounting: installation box, ceiling, or the cover of a lamp or appliance. Mounting position: any.
* Keep at least 1 cm from other iNELS units. Never mount in a metal box or metal switchboard — it blocks the radio signal.
* For indoor use only.

Wiring diagram: see page 1 of the [instruction manual (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFSA-11B/EN/Manual_RFSA-x1B.pdf).

## Programming card

|                                        | RFSA-11B                                                                           |
| -------------------------------------- | ---------------------------------------------------------------------------------- |
| Manual on/off                          | PROG < 1 s                                                                         |
| **Enter programming**                  | **Hold PROG until the LED flashes once per second**                                |
| Finish programming                     | PROG < 1 s                                                                         |
| **Clear one button**                   | **PROG 5 s**                                                                       |
| **Clear whole memory (factory reset)** | **PROG 8 s**                                                                       |
| Function                               | ON/OFF only — press the button **once**                                            |
| Buttons                                | up to 25                                                                           |
| Pairs with                             | All iNELS RF Control and RF Control2 controllers and system units; RFIO2 detectors |

## Pair a controller button

{% stepper %}
{% step %}

### Controller into pairing mode

Hold the controller's pairing button 1 s (red LED short blink). Older controllers: [Pairing reference](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md).
{% endstep %}

{% step %}

### Unit into programming mode

Hold PROG until the LED flashes once per second.
{% endstep %}

{% step %}

### Press the controller button once

Press the button you want to use **one time**. That button now switches the output **on**. The second half of the same control (for a 4-button controller: the other half of the same rocker) gets **off** automatically. The LED lights at the press, so you can see the unit received it.
{% endstep %}

{% step %}

### Finish

Short press PROG (< 1 s). The LED shows the memory-function setting and the unit returns to operation.
{% endstep %}
{% endstepper %}

## Memory function

Decides what the output does after a power cut.

1. Put the unit into programming mode (as above).
2. Short press PROG (< 1 s). This **reverses** the memory setting and leaves programming mode.
3. The LED shows the new setting: **3 blinks = on**, **one long light = off**.

| Setting | After a power cut                                               |
| ------- | --------------------------------------------------------------- |
| On      | Output returns to its last state (saved 15 s after each change) |
| Off     | Output stays off                                                |

## Clear and factory reset

**One button.** Hold PROG **5 s** — LED flashes 4× per second. Press the controller button to remove. One long flash confirms.

**Whole memory = factory reset.** Hold PROG **8 s** — LED flashes 4× per second. All buttons are removed; the unit stays in programming mode (LED every 0.5 s, up to 4 min). Short press PROG (< 1 s) to leave.

Clearing does not change the memory-function setting.

## Use with eLAN-204 and service tools

* The **address printed on the front** of the unit is used to program it from system units and to add it to a gateway.
* To add it to an [eLAN-204](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204.md) gateway: open the Devices tab, press **ADD device**, choose the model from the list, enter the RF address shown on the unit, then choose an icon and a name ([Web interface tabs](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204/web-interface-tabs-description.md)).
* The **repeater function** can be switched on with the RFAF/USB service device (units marked RF Control2 / RFIO2).

## LED reference

| LED                             | Meaning                                             |
| ------------------------------- | --------------------------------------------------- |
| Flashes once per second         | Programming mode                                    |
| Lights at each controller press | Command received (in programming and clearing mode) |
| Flashes 4× per second           | Clear mode                                          |
| Flashes every 0.5 s             | Memory cleared, waiting in programming mode         |
| 3 blinks / one long light       | Memory function on / off                            |

## Troubleshooting

| Symptom                                             | Fix                                                                                                                                                                                                                                |
| --------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Unit flashes 4× per second when you try to pair     | PROG held too long (that is clear mode). Release, wait, hold again until the LED flashes once per second                                                                                                                           |
| Button only switches on, or only off                | Pair the button once; the opposite half of the control gets the other command automatically. Clear and pair again                                                                                                                  |
| Works close by, not in place                        | Range — see [How programming works](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md). Metal boxes and switchboards block the signal. Use an RFRP-20 repeater or an RFIO2 unit with the repeater function |
| Light comes on / does not come on after a power cut | Change the memory function                                                                                                                                                                                                         |

## Technical parameters

|                                   | RFSA-11B                                       |
| --------------------------------- | ---------------------------------------------- |
| Supply                            | 230 V AC, 50–60 Hz, +10 % / −15 %              |
| Apparent input / dissipated power | 7 VA (cos φ = 0.1) / 0.7 W                     |
| Output                            | 1 × switching, AgSnO₂                          |
| Rated current / switching power   | 16 A / AC1, 4000 VA / AC1, 384 W / DC          |
| Peak current                      | 30 A / < 3 s                                   |
| Switching voltage                 | 250 V AC1 / 24 V DC                            |
| Min. DC switching power           | 500 mW                                         |
| Service life                      | mechanical 3 × 10⁷, electrical (AC1) 0.7 × 10⁵ |
| Protocol / frequency              | RFIO2, bidirectional, 866–922 MHz              |
| Repeater function                 | yes                                            |
| Range                             | up to 200 m in open space                      |
| Operating temperature             | −15 to +50 °C                                  |
| Protection                        | IP30                                           |
| Overvoltage category / pollution  | III / 2                                        |
| Leads (CY wire)                   | 2 × 0.75 mm², 2 × 2.5 mm², 90 mm long          |
| Dimensions / weight               | 49 × 49 × 21 mm / 46 g                         |
| Standards                         | EN 60669, EN 300 220, EN 301 489               |

Load capacity for other load types: see the catalog *Product loadability* table (16 A AgSnO₂ contacts).