> For the complete documentation index, see [llms.txt](https://wiki.inels.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/receivers/dimmers/rfdac-71b-sl.md).

# RFDAC-71B-SL

RFDAC-71B-SL, the analog controller with a 0(1)-10 V output — for dimmable ballasts, LED drivers and thermal actuators. Wiring, pairing, output mode, specs.

*Part 3 — Unit reference · Dimmers.*

This unit does not dim a lamp directly. It gives a **0(1)–10 V control signal** (a potential-free analog output) to a device that has such a control input — for example a luminaire or a dimmable ballast, or a thermal actuator or thermal head. It also has a relay contact that switches the phase. It is small enough for an installation box, a ceiling or a lamp cover.

![RFDAC-71B-SL — analog controller, 0(1)–10 V output, relay 8 A](https://2503278529-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FkoLW6hWCvDgagoswDVfD%2Fuploads%2Fou01C4pwgOfEw6bQ2HPT%2Frfdac-71b-sl.png?alt=media)

{% hint style="info" %}
**This unit is paired differently from the other dimmers.** The PROG button times are not the same as on the other dimmers, so **follow the LED**: hold PROG until the LED flashes once per second to enter programming mode, and, when clearing, until it flashes 4× per second. See the programming card below.
{% endhint %}

The dimmer functions (1× to 8× presses) are the same as on every iNELS Wireless dimmer — see the [Dimmers](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/receivers/dimmers.md) page.

## At a glance

|                     | RFDAC-71B-SL                                                           |
| ------------------- | ---------------------------------------------------------------------- |
| Supply              | 110–230 V AC, 50–60 Hz                                                 |
| Analog output       | 0(1)–10 V, potential-free, max. 10 mA                                  |
| Relay contact       | 1 × AgSnO₂, switches the phase conductor (L); 8 A / AC1, 2000 VA / AC1 |
| Wireless buttons    | up to 25                                                               |
| Range in open space | up to 200 m                                                            |
| Repeater function   | Yes                                                                    |
| Mounting            | Installation box, ceiling or lamp cover (BOX design)                   |
| EAN                 | 8595188182676                                                          |

## Wiring

{% hint style="danger" %}
Switch the circuit off before wiring. Never mount the unit in a metal box. Keep at least 1 cm from other units.
{% endhint %}

| No. | Part                    | Connect                                                             |
| --- | ----------------------- | ------------------------------------------------------------------- |
| 1   | PROG button and LED     | — (status indication, programming and manual control of the output) |
| 2   | Phase conductor         | L                                                                   |
| 3   | Switched output contact | L switched by the relay                                             |
| 4   | Neutral conductor       | N                                                                   |
| 5   | Analog output           | 0(1)–10 V to the control input of the controlled device             |

* The datasheet has two connection examples: **a fluorescent tube with a dimmable ballast**, and **a thermo-valve** (24 V AC to the valve, the 0–10 V from this unit). See the [datasheet](https://www.elkoep.com/media/import/Elko/RFx/RFDAC-71B-SL/EN/Datasheet_RFDAC-71B-SL.pdf).
* Connection wires: 3 × 0.75 mm² and 2 × 2.5 mm² (datasheet).
* Wiring diagram: see the [instruction sheet (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFDAC-71B-SL/EN/Manual_RFDAC-71B-SL.pdf), page 1.

## Output voltage: 0–10 V or 1–10 V

The unit can give a 0–10 V or a 1–10 V signal. Press PROG for **1 to 3 s** and release; the LED then flashes in the colour of the chosen mode: **green = 0–10 V, red = 1–10 V**.

## Programming card

|                        | RFDAC-71B-SL                                                                                                                  |
| ---------------------- | ----------------------------------------------------------------------------------------------------------------------------- |
| Manual on/off          | PROG < 1 s                                                                                                                    |
| Choose 0–10 V / 1–10 V | PROG 1–3 s                                                                                                                    |
| **Enter programming**  | **Hold PROG until the LED flashes once per second**                                                                           |
| Finish programming     | PROG < 1 s                                                                                                                    |
| Timing mode (5× / 6×)  | PROG more than 5 s                                                                                                            |
| **Clear one button**   | **Hold PROG until the LED flashes 4× per second**, then press the controller button to remove                                 |
| **Clear whole memory** | See the [instruction sheet](https://www.elkoep.com/media/import/Elko/RFx/RFDAC-71B-SL/EN/Manual_RFDAC-71B-SL.pdf) of the unit |
| Functions              | [1× to 8×](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-b-functions-by-number-of-presses.md)          |
| Pairs with             | All iNELS RF Control and RF Control2 controllers and system units                                                             |

{% hint style="info" %}
Follow the LED: hold PROG until it flashes once per second (programming mode), and while clearing, until it flashes 4× per second. See also [Appendix A](https://wiki.inels.com/inels-home/inels-wireless/appendices/appendix-a-prog-button-times.md).
{% endhint %}

## Pair a controller button

The steps are the same as on the other dimmers. Only the PROG time differs (see the card above).

{% stepper %}
{% step %}

### Controller into pairing mode

Hold the controller's pairing button 1 s (red LED short blink). Older controllers: [Pairing reference, section B](https://wiki.inels.com/inels-home/inels-wireless/pairing-and-configuration.md).
{% endstep %}

{% step %}

### RFDAC-71B-SL into programming mode

Hold PROG until the LED flashes once per second.
{% endstep %}

{% step %}

### Choose the function

Press the controller button **1 to 8 times, about 1 s apart** ([Dimmers](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/receivers/dimmers.md)). The LED lights briefly at every press.
{% endstep %}

{% step %}

### Finish

Short press PROG (< 1 s). The LED shows the memory-function setting.
{% endstep %}
{% endstepper %}

For sunrise and sunset (5× and 6×): after the presses, hold PROG more than 5 s (LED flashes twice per second), wait for the time you want the fade to take (2 s to 30 min), press the same controller button once, then short press PROG.

## Memory of brightness

* **The level you set.** On scenes 1–4, when you let go of the button after a long press, the level is stored. Later short presses switch to and from that level, and it is kept after a power cut. When the output is switched off the set level is stored and it returns when switched on.
* **The state after a power cut (memory function).** The memory status can be pre-set. To change it, enter programming mode and then short press PROG (< 1 s): this **reverses** the setting. The LED shows the new setting: **3 blinks = on**, **one long light = off**. With the memory on, functions 1–4, 7 and 8 return to the last state (saved 15 s after each change); with it off, the output stays off when the power returns.

## Clear and factory reset

The LED flashes 4× per second while clearing. **One button:** hold PROG until the LED flashes 4× per second, then press the controller button to remove it; one long flash confirms. **Whole memory:** see the [instruction sheet](https://www.elkoep.com/media/import/Elko/RFx/RFDAC-71B-SL/EN/Manual_RFDAC-71B-SL.pdf) of the unit; the unit then stays in programming mode (LED flashes every 0.5 s, up to 4 minutes) and a short press of PROG leaves it. Clearing does not change the memory-function setting.

## Use with eLAN-204 and service tools

The **address printed on the front** is used to program the unit from system units and to add it to a gateway such as the [eLAN-204](https://wiki.inels.com/inels-home/inels-wireless/technical-manual-devices/system-units/elan-204.md). The repeater function is set with the RFAF/USB service device. The datasheet gives a minimum control distance of 20 mm.

## LED reference

| LED                          | Meaning                                      |
| ---------------------------- | -------------------------------------------- |
| Green / red                  | Chosen output mode: green 0–10 V, red 1–10 V |
| Flashes once per second      | Programming mode                             |
| Lights briefly at each press | Command received                             |
| Flashes twice per second     | Timing mode                                  |
| Flashes 4× per second        | Clear mode                                   |
| Flashes every 0.5 s          | Memory cleared, waiting in programming mode  |
| 3 blinks / one long light    | Memory function on / off                     |

## Troubleshooting

| Symptom                                             | Fix                                                                                                                    |
| --------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------- |
| Pairing does not start                              | The PROG time of this unit differs from the other dimmers. Hold PROG until the LED flashes once per second             |
| LED flashes 4× per second                           | You are in clear mode. Release and wait; do not hold PROG that long                                                    |
| Light is not fully dimmable / lowest level is wrong | Check the output mode: 0–10 V or 1–10 V must match the controlled device                                               |
| Wrong function after pairing                        | Presses too fast. Keep about 1 s between presses; clear and pair again                                                 |
| Works close by, not in place                        | Range — see [How programming works § Range](https://wiki.inels.com/inels-home/inels-wireless/how-programming-works.md) |

## Technical parameters

|                                   |                                                 |
| --------------------------------- | ----------------------------------------------- |
| Supply                            | 110–230 V AC, 50–60 Hz, +10 % / −15 %           |
| Apparent input / dissipated power | 7 VA (cos φ = 0.1) / 0.7 W                      |
| Analog output                     | 0(1)–10 V, potential-free, max. 10 mA           |
| Relay contact                     | 1 × AgSnO₂, switches the phase conductor        |
| Rated current / switching power   | 8 A / AC1, 2000 VA / AC1                        |
| Switching voltage                 | 250 V AC1                                       |
| Service life                      | mechanical 3 × 10⁷, electrical 1 × 10⁵          |
| Protocol / frequency              | RFIO2, up to 25 channels (buttons), 866–922 MHz |
| Repeater function                 | yes                                             |
| Range / minimum control distance  | up to 200 m in open space / 20 mm               |
| Operating temperature             | −15 to +50 °C                                   |
| Position / protection             | any / IP40                                      |
| Overvoltage category / pollution  | III / 2                                         |
| Connection wires                  | 3 × 0.75 mm², 2 × 2.5 mm²                       |
| Dimensions / weight               | 49 × 49 × 21 mm / 43 g                          |
| Standards                         | EN 60730, EN 63044, EN 300 220, EN 301 489      |

Typical uses of the 0(1)–10 V output: dimming fluorescent lamps with a dimmable ballast, dimming LED panels with a suitable dimmed source (up to 50 pieces LP-6060-3K / 6K), controlling thermal actuators (TELVA), and controlling other controllers such as the DIM-6 power dimmer.

## Downloads

* [Instruction sheet RFDAC-71B-SL (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFDAC-71B-SL/EN/Manual_RFDAC-71B-SL.pdf)
* [Datasheet (PDF)](https://www.elkoep.com/media/import/Elko/RFx/RFDAC-71B-SL/EN/Datasheet_RFDAC-71B-SL.pdf)