Appendix C: Which transmitter works with which receiver
The rules for which controllers and detectors can be paired with which receivers: RFIO and RFIO2, old and new controllers, compatibility mode.
Appendices. Read with the Pairing reference.
Most iNELS Wireless transmitters can be paired with most receivers. The exceptions are old controllers, detectors, shutter units and a few units that pair in their own way. This page collects the rules.
1. Quick answer
Controllers with a pairing button (RFWB, RFGB, RF KEY, glass RFSW and RFDW)
Yes
Yes
Yes
Older controllers without a pairing button
Yes, in normal or compatibility mode — see section 4
Yes, same rules
Yes, same rules
Detectors RFMD-100, RFWD-100, RFSF-100
Yes, but only units marked RFIO2
Yes, units marked RFIO2 (for example RFDEL-71B-SL); check the unit's page for others
No — detectors cannot be paired with shutter units
System units (eLAN, RF Touch, RFTC-3)
Yes, by the address printed on the unit
Yes, same
Yes, same
2. RFIO and RFIO2
The radio language of the system is called RFIO. A newer version, RFIO2, is fully compatible with RFIO and adds more. Units that carry the RFIO2 mark can do the following:
Work with older RFIO products. Backward compatibility is kept.
Act as a repeater for other units. This is switched on with the RFAF/USB service key.
Have their firmware updated with the RFAF/USB service key.
Communicate with the RFMD-100 and RFWD-100 detectors.
Pass on messages: other receivers in range can help carry a message to a receiver that is out of reach.
In unit manuals the same family is also written as "iNELS RF Control2 (RFIO2)". Older manuals call the whole system "iNELS RF Control".
3. Old and new controllers
Controllers come in two generations, by factory version.
Pairing button and symbol on the back
Yes
No
How you start pairing
Hold the pairing button 1 s (Pairing reference, section A)
Remove the battery for at least 5 s and put it back (section B)
Pairing mode
Always the "RFIO2" way: controller and unit both go into pairing mode
Normal mode (double flash) or compatibility mode (fast flash)
Newly produced controllers work in RFIO2 mode and are taught to a unit differently from before. This prevents a random controller in range from being learned by mistake. A controller can still be switched into compatibility mode to pair the older, simpler way.
Which mode is my controller in?
Double flash (flash, flash, gap, flash, flash)
Normal / RFIO2 mode
Fast flashing
Compatibility mode
To change the mode, remove the battery for at least 5 s and put it back. While the red LED is lit (3 s), press and hold two buttons together until the LED shows the new mode, then release:
RFWB, RFGB (standard)
1 and 2
RF KEY-40 / RF KEY-60
1 and 3
Keep holding until the LED shows the new mode (double flash or fast flashing), then release.
Controllers that have a PROG button offer a second way: hold it for 8 s. The LED under the button lights while it is held. After 8 s it shows the new mode with double flash or fast flashing. Each 8 s press switches to the other mode.
4. Rules for the oldest controllers
You cannot tell in advance whether an older controller and an older unit need compatibility mode. Try normal mode first, then compatibility mode. (Pairing reference, section B)
The oldest RF Key/W and RF Key/B key fobs, and other controllers of the oldest version, cannot be paired with units that have the radio-wave mark on the PROG button.
RFSAI-62B-SL, RFSA-62B and RFDAC-71B pair differently from other units. Follow their own page.
In compatibility mode the number of presses gives functions 1–6 for switch units and 1–8 for dimmers.
Leave 1 s between presses in every mode.
5. Which function table does a receiver use?
The number of presses means different things on different receivers.
Switch units, multi-function
RFSA-61B, RFSA-62B, RFSA-61M, RFSA-61MI, RFSA-66M, RFSA-66MI, RFSAI-61B-SL, RFSAI-62B-SL, RFSC-61N, RFUS-61
1×–6×
Switch units, single function
RFSA-11B, RFSAI-11B-SL
1× (the button below gets OFF automatically)
Shutter units
RFJA
Not counted: first button = up, the other half of the rocker = down
6. Detectors
A detector behaves like a controller, but it is paired when the batteries are inserted, and it needs a receiver marked RFIO2.
RFWD-100 window/door
RFSA-61B, RFSA-62B, RFSAI-61B, RFSA-61M, RFSA-66M, RFSC-61, RFUS-61 (only units marked RFIO2). System units eLAN-RF-003, eLAN-RF-Wi-003
RFSF-100 flood
All switching units of the system except blind units that are marked RFIO2 (for example RFSA-11B, RFSA-61M, RFSA-66M, RFUS-61, RFSC-61). System units eLAN-RF, RF Touch, iNELS BUS central units CU3-0xM
RFMD-100 motion
Switching units marked RFIO2 and eLAN-RF system units
The detector's DIP switch tells it whether it is paired directly with a unit (position OFF) or connected to a system unit such as a gateway (position ON). See Tutorial 5 for where the switch is.
7. Transmitters of the system
These controllers are the transmitters of the system:
Surface or wall mounted: RFWB-20/MPW, RFWB-40/MPW, RFWB-20/G, RFWB-40/G, RFWB-40G/MT, RFGB-20, RFGB-40, RFGB-40B/MT, RFGB-40W/MT, RFGB-220, RFGB-240, RFTC-10/G, RFTC-50/G.
Flush mounted: RFSK-21/MPW, RFDK-21/MPW, RFJK-22/MPW, RF Touch-2, RFDW-71, RFDW-271, RFSW-62, RFSW-62/S, RFSW-22, RFSW-42, RFGS-30/S, RFMB-22, RFMB-42, RFMB-62.
Some of these also have an output of their own (for example RFSK-21/MPW with a relay), so they are transmitter and receiver at once. See Transmitters, receivers and gateways.
See also: Appendix A — PROG button times · Appendix B — Functions by number of presses · Pairing reference
Last updated