Appendix A: PROG button times
How long to hold the PROG button on each iNELS Wireless unit to pair, clear one button, or clear the whole memory.
Appendices. Used by every pairing procedure in this manual.
Every iNELS Wireless receiver has one PROG button. What it does depends on how long you hold it — and those times are not the same on every unit.
How to read the table
Short press
Under 1 s. Manual control of the output — or, in programming mode, finish programming
Output toggles / LED returns to normal
Enter programming
The unit waits for a transmitter button
LED flashes once per second
Clear one button
The next transmitter button you press is removed
LED flashes 4× per second, then one long flash to confirm
Clear whole memory
Factory reset: every paired button is removed; the unit then stays in programming mode
LED flashes 4× per second, then every 0.5 s (up to 4 min)
Factory reset = clear whole memory. There is no separate "hold more than 12 s" step.
PROG times by unit
Where the table says "until the LED flashes once per second", hold PROG and release as soon as the LED starts flashing once per second — that is programming mode.
Switch units
Dimmers
Shutter units and controllers with an output
Other units
RFRP-20N repeater — not programmed with PROG hold times; see its page.
RFSOU-1 twilight switch — programming starts by pressing PROG while inserting the batteries; see its page.
Thermostats (RFTC), the eLAN gateways, RF Touch-2 — not programmed with PROG times; see their own pages.
Units with no PROG button
Transmitters — wall controllers, key fobs, detectors, input modules and sensors — do not have a PROG button that you hold. They are paired from their own pairing button or by inserting the battery, and the PROG time that matters is the one of the receiver you are pairing them to. See the Pairing reference.
See also: Appendix B — Functions by number of presses · Pairing reference