Basic Information

Power Supply:

110–230 V AC

Network Connection:

  • MB-1 has a Wi-Fi interface (2.4 GHz).

  • Maximum number of connected RF devices is 20.

  • For the initial connection, you need to connect to the access point (AP) created by the device in setup mode.

  • AP name: MiniBridge_SN

  • AP password: elkoep_1

  • Default IP address of the device in AP mode: 192.168.1.1

  • After connecting to the AP, open the web interface in a browser at http://192.168.1.1arrow-up-right

– no password is required for access.


Prog Button

  • If the button is held for less than 750 ms, the relay turns On/Off.

  • If held for more than 750 ms but less than 2500 ms, it changes the relay channel.

  • If held for more than 2500 ms but less than 5000 ms, it activates key fob learning and function assignment.

  • If held for more than 5000 ms but less than 8000 ms, it activates delay-off and delay-on time learning.

  • If held for more than 8000 ms but less than 11000 ms, it deletes one button.

  • If held for more than 11000 ms but less than 15000 ms, it deletes all learned buttons.

  • If held for more than 15000 ms but less than 19000 ms, it turns the Wi-Fi Access Point On/Off.

  • If held for more than 19000 ms but less than 25000 ms, it performs a factory reset.