Appendix D — Supported units

What iDM3 3.5.3 can configure.


This list will age. The software will not. The authoritative sources ship with your copy of iDM3 and are always current for the revision you have:

Check those before ordering hardware.

File
Contents

Advance/Firmwares\

A firmware package per supported unit and version

Advance/Documentation/Recommended minimal firmware version.txt

Minimum firmware per unit

Advance/Documentation/Firmware history\

Per-unit change history

Advance/Documentation/BUS unit to MQTT.txt

Which units can publish to MQTT

Advance/Documentation/Change log.txt

Which units each revision added


Central units

Unit
Status

CU3-08M

Current — use this for new installations

CU3-09M

Current

CU3-10M

Current

CU3-07M

Obsolete. Supported for servicing existing sites only.


The units used in this manual

Role
Unit
Appears in

Central unit

CU3-08M

throughout

Wall buttons

GSB3-40

Relay outputs

SA3-02M

Dimmer

DA3-22M

Blind actuator

JA3-02B/DC

Room thermostat

GRT3-50

GSM module

GSM3-01M

Binary inputs

IM3-40B


Bus master and virtual modules

Added with New slave under the central unit.

Module
Kind
Notes

Internal-Master/BUS1

internal

The CU's own bus. Address fixed.

Internal-Master/BUS2

internal

Second internal bus

Internal-RF-Master

internal

RF units

MI3-02M/BUS

external

Up to 16 modules

MI3-02M-INELS2/BUS

external

Up to 16 modules

EMDC-64M/DALI-DMX

external

Up to 16 modules; up to 20 virtual DALI-DMX units each

GSM3-01M

external

Maximum 3 per project

Astronomical-Module

virtual

Maximum 1. Sunrise, sunset, moon phase

EZS-Module

virtual

Security system

HC-Circuit-Module

virtual

Heating/cooling circuits

Regulators-Module

virtual

Regulators

Modbus-IP-Master / Modbus-IP-Slave

external

Limits: 20 system modules on the CU's EBM bus · 32 units per BUS line · 32 RF addresses, though some RF units occupy more than one.


Units with firmware in this release

Every unit with a firmware package in Advance/Firmwares\116 entries, including modules, virtual units and regulators as well as physical devices.

A-IBUS-SLAVE

FA3-612M-RELAY

HC-CIRCUIT-MODULE

MODBUS-IP-MASTER

ADC3-60M

FAN-COIL-REGULATOR

HEAT-REGULATOR

MODBUS-IP-MASTER-UNIT

ASTRONOMICAL-MODULE

GBP3-60

HOTEL-ROOM

MODBUS-IP-SLAVE

ASTRONOMICAL-UNIT

GCH3-31

HOTEL-ROOM-MODUL

MODBUS-IP-SLAVE-UNIT

BIN3-66B

GCR3-11

IBWL-02B

MODBUS-UNIT

CONTROLLER

GCR3-30

IBWL-20B

MSB3-40

COOL-REGULATOR

GDB3-10

IDRT3-1

MSB3-60

CU3-07M

GDB3-30

IM3-140M

MSB3-90

CU3-08M

GMR3-61

IM3-20B

PMS3-01

CU3-09M

GMR3-61-VS

IM3-40B

RC3-610M-DALI

CU3-10M

GRT3-100

IM3-80B

REGULATORS-MODULE

DA3-03M-RGBW

GRT3-100-MODBUS-MASTER

IN-OUT-CU3-01M-CU3-02M

RPD3-01

DA3-22M

GRT3-50

INTERNAL-DALI-MASTER

SA3-012M

DA3-66M

GRT3-50-V3

INTERNAL-IN-OUT-MASTER-CU3-01M-CU3-02M

SA3-014M

DAC3-04B

GRT3-70

INTERNAL-MASTER

SA3-01B

DAC3-04M

GSB3-20SX

INTERNAL-MODBUS

SA3-022M-RELAY

DALI-DMX-UNIT

GSB3-40

INTERNAL-MODBUS-MASTER

SA3-02B

DALI-DMX-UNIT-02

GSB3-40-V2

INTERNAL-RF-MASTER

SA3-02M

DATE-TIME-UNIT

GSB3-40SX

IOU3-108M

SA3-04M

DCDA-33M

GSB3-40SX-V2

JA3-014M

SA3-06M

DIFFERENTIAL-REGULATOR

GSB3-60

JA3-018M

TI3-10B

DLS3-1

GSB3-60-V2

JA3-02B

TI3-40B

DLS3-1-DALI

GSB3-60SX

JA3-02BDC

TI3-60M

DMD3-1

GSB3-60SX-V2

LBC3-02M

VALVE-REGULATOR

DMD3-1-DALI

GSB3-80

MATHEMATIC-BASE-UNIT

WMR3-21

EA3-022M-RELAY

GSB3-90-V2

MATHEMATIC-MODUL

WSB3-20

EMDC-64M

GSB3-90SX

MATHEMATIC-STANDARD-UNIT

WSB3-20-HUM

EST3 ⚠️

GSB3-90SX-V2

MCD3-01

WSB3-40

EST3-HOTEL ⚠️

GSP3-100

MI3-02M

WSB3-40-HUM


Obsolete units

These still appear in the unit lists so you can open and service existing projects. Do not specify them for new work.

Unit
Replace with

EST3

A current glass switch — GSB3 series

EST3-HOTEL

GSB3 series, with the Hotel-Room object for room state

EHT3

GSB3 series

CU3-07M

CU3-08M or newer (Chapter 1)

The hotel panels in particular carried their own SW-DND / SW-MUR / Backlight SW-… devices. On a current installation those functions come from ordinary GSB3 buttons wired to the Hotel-Room object's datapoints — see Chapter 34 §34.6.


MQTT-capable units

Around 50 unit types can publish to MQTT, along with CU status, gateway status, system bits and system integers. They include the ADC3, DA3, DAC3, GSB3 (including -V2 and /S variants), MSB3, WSB3 (including -Hum), IM3, JA3 and SA3 families, plus GRT3-50, IDRT3-1, IOU3-108M, GBP3-60, GCH3-31, GCR3-11, GDB3-10, GSP3-100, DMD3-1 and RC3-610M/DALI.

Requires CU firmware 02.97.02 or later.

The definitive list is Advance/Documentation/BUS unit to MQTT.txt.


Unit modules with a graphical view

These 49 unit types have a dedicated terminal diagram in iDM3, showing their connections:

ADC2_40M

GSB3-40

IM3-20B

SA3-06M

ADC3_60M

GSB3-40SB

IM3-40B

SingleButton

DA3-22M

GSB3-60

IM3-80B

TI2_40B

DAC3-04B

GSB3-60SB

JA2_02B

TI3_10B

DAC3-04M

GSB3-80

JA2_02BDC

TI3_40B

DCDA_33M

GSM3_01M

JA3_02BDC

TI3_60M

EST3 ⚠️

GSP3-100

Keyboard

WMR3-21

EZS-Zone

HC2_01BAC

LBC3-02M

WSB2-80

GCH3-31

HC2_01BDC

SA3-012M

WSB3-20

GCR3-11

HRS-Room

SA3-01B

WSB3-40

GMR3-61

Hotel-ROOM

SA3-02B

GRT3-50

IDRT3-1

SA3-02M

GSB3-20SB

IM3-140M

SA3-04M